APAR status
Closed as unreproducible in next release.
Error description
COMPO DESIGN / GRID / UNABLE TO SYNCHRONISE OR GENERATE PLIES. . Scenario. . 1) Open the CATPart and notice that there is no cell coloring, even if the Virtual Stacking is correctly populated. 2) Click on plies synchronization. The command does not work anymore when the coloring disappears. 3) Click on the synchronize stacking icon An error message appears and it is not possible to synchronize. 4) Create a new Virtual Stacking, using Grid.1 as input. 5) The virtual stacking is created and populated, but the cells are not colored. Create plies from this new virtual stacking 6) A new ply group is created (Plies Group.2), but it is empty. 7) If try to synchronize the new Virtual Stacking with the Plies Group.2, an error is received . Expected results: 1) the grid and virtual stacking coloring are visible, 2) the user could synchronize the ply group to the original virtual stacking, and/or 3) the user could generate new plies. .
Local fix
Problem summary
COMPO DESIGN / GRID / UNABLE TO SYNCHRONISE OR GENERATE PLIES. COMPO DESIGN / GRID / UNABLE TO SYNCHRONISE OR GENERATE PLIES. . Scenario. . 1) Open the CATPart and notice that there is no cell coloring, even if the Virtual Stacking is correctly populated. 2) Click on plies synchronization. The command does not work anymore when the coloring disappears. 3) Click on the synchronize stacking icon An error message appears and it is not possible to synchronize. 4) Create a new Virtual Stacking, using Grid.1 as input. 5) The virtual stacking is created and populated, but the cells are not colored. Create plies from this new virtual stacking 6) A new ply group is created (Plies Group.2), but it is empty. 7) If try to synchronize the new Virtual Stacking with the Plies Group.2, an error is received . Expected results: 1) the grid and virtual stacking coloring are visible, 2) the user could synchronize the ply group to the original virtual stacking, and/or 3) the user could generate new plies. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON CATIA VERSION 5 RELEASE 18. THIS PROBLEM IS NOT REPRODUCIBLE ON CATIA VERSION 5 RELEASE 20 GA LEVEL. NOTE THAT THE PROBLEM IS NOT REPRODUCIBLE ON V5R19SP03 LEVEL ALSO. Incident Diagnosis synchronization of ply impossible and no color of grid and Virtual Stack. . Correct Application To see correction user needs to upgrade the grid as changes in cells computation has been done (as any other geometrical algorithm it is versionned and hence needs to be upgraded to take benefits of last algorithm). The root cause was that a reference element group was empty in the panel definition and this case was not handled properly with previous version of algorithm. .
APAR Information
APAR number
HD78813
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-16
Closed date
2008-11-24
Last modified date
2009-01-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN SP51903
UP09/01/22 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
22 January 2009