IBM Support

HD78731: ANALYSIS (GSA) / SINGULARITY IS DETECTED WHEN STIFFNESS IS INCR EASED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ANALYSIS (GSA) / SINGULARITY IS DETECTED
    WHEN STIFFNESS IS INCREASED.
    .
    Scenario.
    .
    1. Open Part2.CATAnalysis. If Translation Stiffness
    1 in SmoothSpringVirtualPart.1 was changed,
    Translation Stiffness 2 and 3,in
    SmoothSpringVirtualPart.1 and all Translation
    Stiffness in SmoothSpringVirtualPart.2,3 and 4 are
    followed.
    2. Double Click on Smooth Spring Virtual Part.1
    3. Change the Translation Stiffness 1 to
    5e+010N_m then click OK button.
    4. Click Compute icon.  Computation is completed
    without any error.
    5. Double Click on Smooth Spring Virtual Part.1
    6. Change the Translation Stiffness 1 to
    5e+020N_m then click OK button.
    7. Click Compute icon.  Error message is
    displayed.
    This is a problem.
    .
    Expected result:
    Computation should be completed without any
    error.
    .
    

Local fix

Problem summary

  • ANALYSIS (GSA) / SINGULARITY IS DETECTED WHEN STIFFNESS IS INCR
    EASED.
    ANALYSIS (GSA) / SINGULARITY IS DETECTED
    WHEN STIFFNESS IS INCREASED.
    .
    Scenario.
    .
    1. Open Part2.CATAnalysis. If Translation Stiffness
    1 in SmoothSpringVirtualPart.1 was changed,
    Translation Stiffness 2 and 3,in
    SmoothSpringVirtualPart.1 and all Translation
    Stiffness in SmoothSpringVirtualPart.2,3 and 4 are
    followed.
    2. Double Click on Smooth Spring Virtual Part.1
    3. Change the Translation Stiffness 1 to
    5e+010N_m then click OK button.
    4. Click Compute icon.  Computation is completed
    without any error.
    5. Double Click on Smooth Spring Virtual Part.1
    6. Change the Translation Stiffness 1 to
    5e+020N_m then click OK button.
    7. Click Compute icon.  Error message is
    displayed.
    This is a problem.
    .
    Expected result:
    Computation should be completed without any
    error.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    Incident Diagnosis
    Singularity is detected when stiffness is increased.
    Restriction Explanation
    The stiffness introduces in the spring leads to an ill
    condition stiffness matrix. Thus causing singualarity
    error.
    However user has to note that the stiffness value is
    too big in this case.
    By-Pass
    If the stiffness is too big, then use rigid element.
    Note : When Translation Stiffness 1 is changed to
    5e+040N_m and compute is done, please check
    the translational displacement magnitude image.
    This shows value as zero, as element is highly stiff.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD78731

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-10-14

  • Closed date

    2008-10-17

  • Last modified date

    2008-10-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
17 October 2008