IBM Support

HD77753: KNOWLEDGE ADVISOR:REACTION ERROR OF KNOWLEDGE IS DISPLAYED IF T HE PARAMETER IS CHANGED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as user error.

Error description

  • KNOWLEDGE ADVISOR:REACTION ERROR OF
    KNOWLEDGE IS DISPLAYED IF THE PARAMETER IS
    CHANGED.
    .
    SETTINGS:
    1)Tool-Option Setting
    2)Options / General/ Parameters and
    Measure / "Knowledge" tab
    3)Parameter Tree View -"With value" , "With
    formula" = Active
    4)Options / Infrastructure/ Part
    Infrastructure / "Display" tab
    5)Display In Specification Tree-
    "Parameters" , "Relations" = Active
    .
    Information of Reactions:
    Reaction.2 and Reaction.3 are defined the following
    knowledge actions.
    .
    SCENARIO:
    1)Start CATIA V5R17SP08.
    2)Open the file : "Part.CATPart".
    (Workbench : "GSD" )
    3)Edit the Boolean Parameter.
    3-1)Double Click "Boolean.1" in the tree="Edit
    Parameter" dialog box is displayed.
    3-2)Change the value: true="Reaction.3" dialog
    box is displayed.
    3-3) Click "OK" button in message dialog
    box=Parameter can be changed without Error.
    =This is the right behavior.
    3-4) Change the value: false="Reaction.3" dialog
    box is displayed.
    3-5) Click "OK" button in message dialog box.
    =Parameter can be changed without Error.
    =This is the right behavior.
    Not OK Process:
    .
    1)Start CATIA V5R18SP05.
    2)Open the file :"Part.CATPart".
    (Workbench : "GSD" )
    3) Edit the Boolean Parameter.
    3-1)Double Click "Boolean.1" in the tree="Edit
    Parameter" dialog box is displayed.
    3-2)Change the value: true="Reaction.3" dialog
    box is displayed.
    3-3) Click "OK" button in message dialog
    box="Knowledge Report" is displayed!!
    =This is the problem!!
    3-4)Click "Close" button in the "Knowledge Report".
    3-5)Change the value: false="Reaction.3" dialog
    box is displayed.
    3-6)Click "OK" button in message dialog
    box="Knowledge Report" is displayed.
    =This is the problem.
    .
    .
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Incident Diagnosis:
    REACTION ERROR OF KNOWLEDGE IS DISPLAYED
    IF THE PARAMETER IS CHANGED.
    .
    Correct Application:
    As a design specification, the "Update Method"
    performs the update of a feature when necessary.
    Its scope is limted to relations sets, parameters
    sets, parameters, rule bases, constraints
    satisfactions,
    optimizations, and Knowledge pattern features. It
    has no impacts on the other objects.
    Kindly refer Doc reference given at the end of this
    explanation.
    Considering this defination, "Update Method" not
    applies to object line from given scenario.
    This behavior is similar on regression (R17SP08)
    and on reported (R18SP05) level.
    Hence from function point of view, it should not be
    considered as regression.
    .
    On R17SP08 level also , the line object was not
    updating, even it defined in reaction.
    In order to bring this point in users notice, we have
    added check on R18 level.
    Now the error message user getting on R18SP05
    level is nothing but such message.
    .
    Documentation Reference:
    Knowledge Advisor
    Getting Started
    Engineering Knowledge Language,
    Update method
    .
    

APAR Information

  • APAR number

    HD77753

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED USE

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-09-10

  • Closed date

    2008-09-12

  • Last modified date

    2008-09-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 September 2008