APAR status
Closed as user error.
Error description
KNOWLEDGE ADVISOR:REACTION ERROR OF KNOWLEDGE IS DISPLAYED IF THE PARAMETER IS CHANGED. . SETTINGS: 1)Tool-Option Setting 2)Options / General/ Parameters and Measure / "Knowledge" tab 3)Parameter Tree View -"With value" , "With formula" = Active 4)Options / Infrastructure/ Part Infrastructure / "Display" tab 5)Display In Specification Tree- "Parameters" , "Relations" = Active . Information of Reactions: Reaction.2 and Reaction.3 are defined the following knowledge actions. . SCENARIO: 1)Start CATIA V5R17SP08. 2)Open the file : "Part.CATPart". (Workbench : "GSD" ) 3)Edit the Boolean Parameter. 3-1)Double Click "Boolean.1" in the tree="Edit Parameter" dialog box is displayed. 3-2)Change the value: true="Reaction.3" dialog box is displayed. 3-3) Click "OK" button in message dialog box=Parameter can be changed without Error. =This is the right behavior. 3-4) Change the value: false="Reaction.3" dialog box is displayed. 3-5) Click "OK" button in message dialog box. =Parameter can be changed without Error. =This is the right behavior. Not OK Process: . 1)Start CATIA V5R18SP05. 2)Open the file :"Part.CATPart". (Workbench : "GSD" ) 3) Edit the Boolean Parameter. 3-1)Double Click "Boolean.1" in the tree="Edit Parameter" dialog box is displayed. 3-2)Change the value: true="Reaction.3" dialog box is displayed. 3-3) Click "OK" button in message dialog box="Knowledge Report" is displayed!! =This is the problem!! 3-4)Click "Close" button in the "Knowledge Report". 3-5)Change the value: false="Reaction.3" dialog box is displayed. 3-6)Click "OK" button in message dialog box="Knowledge Report" is displayed. =This is the problem. . .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Incident Diagnosis: REACTION ERROR OF KNOWLEDGE IS DISPLAYED IF THE PARAMETER IS CHANGED. . Correct Application: As a design specification, the "Update Method" performs the update of a feature when necessary. Its scope is limted to relations sets, parameters sets, parameters, rule bases, constraints satisfactions, optimizations, and Knowledge pattern features. It has no impacts on the other objects. Kindly refer Doc reference given at the end of this explanation. Considering this defination, "Update Method" not applies to object line from given scenario. This behavior is similar on regression (R17SP08) and on reported (R18SP05) level. Hence from function point of view, it should not be considered as regression. . On R17SP08 level also , the line object was not updating, even it defined in reaction. In order to bring this point in users notice, we have added check on R18 level. Now the error message user getting on R18SP05 level is nothing but such message. . Documentation Reference: Knowledge Advisor Getting Started Engineering Knowledge Language, Update method .
APAR Information
APAR number
HD77753
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-09-10
Closed date
2008-09-12
Last modified date
2008-09-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
12 September 2008