  • ABSTRACT:
    DMU SPA:Predefined settings change by
    themselves when exporting Interference via macro
    SCENARIO:
    1. Start CATIA V5
    2. Open "Product1.CATProduct" with "File - Open".
    It contains two parts with two cubes and the
    Interference.1
    3. Switch the workbench to "DMU Navigator"
    4. Export the "Interference.1" by executing the
    provided macro
    5. Click OK in the warning message
    with "Interference.1".
    Result:
    Open "Tools | Options | Digital Mockup | DMU
    Space Analysis | DMU Clash-Process" and check
    the settings it is changed from the default one .
    * XML Export for clash process purpose - OFF
    * Federated XML output - ON and dimmed
    * Picture generated in XML - OFF and dimmed
    * Browser automatically opned - ON and dimmed
    .
    

Local fix

Problem summary

  • Predefined settings change by themselves when exporting
    Interference via macro
    ABSTRACT:
    DMU SPA:Predefined settings change by
    themselves when exporting Interference via macro
    SCENARIO:
    1. Start CATIA V5
    2. Open "Product1.CATProduct" with "File - Open".
    It contains two parts with two cubes and the
    Interference.1
    3. Switch the workbench to "DMU Navigator"
    4. Export the "Interference.1" by executing the
    provided macro
    5. Click OK in the warning message
    with "Interference.1".
    Result:
    Open "Tools | Options | Digital Mockup | DMU
    Space Analysis | DMU Clash-Process" and check
    the settings it is changed from the default one .
    * XML Export for clash process purpose - OFF
    * Federated XML output - ON and dimmed
    * Picture generated in XML - OFF and dimmed
    * Browser automatically opned - ON and dimmed
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON ENOVIA VERSION 5 RELEASE
    20 GA LEVEL.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP02
    Incident Diagnosis
    Predefined settings change by themselves when
    exporting Interference via macro.
    Correction Explanation
    Check for the CExportProcess setting of the
    ClashPublish repository. Set it to 0 if it is not found.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD77375

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-08-27

  • Closed date

    2008-09-23

  • Last modified date

    2008-11-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN SP51902

       UP08/11/07 I 1000