APAR status
Closed as documentation error.
Error description
CATIA Link tab isn't displayed for CATIA Design Table when it is opened as read-only and linked to a CATPart Abstract: Customer is able to save a new CATIA document with Microsoft Excel file as design table object which already in Vault (checked in/released). In this case SmarTeam Save operation will successfully processed, but a result will be wrong, because Microsoft Excel object will not be modified and will not take CATIA behavior. Workaround: Perform Check Out/New Release of the Microsoft Excel object before. Scenario: 1. Start SmarTeam Editor and login as joe. 2. Choose some project and select some folder 3. Right-click on the folder and choose Add > CATIA Design Table 5. Then new object Profile Card will open choose DesignTable_test1.xls. as Excel file 6. Check-In the saved object with keep local file 7. Close Editor 8. Start CATIA V5 and SmarTeam > Connect then login as joe. 9. In CATIA session, File > Open and select Part1.CATPart. 10. Click "Design Table" icon then click OK. 11. Select DesignTable_test1.xls under SmarTeam/Work directory. 12. Click Yes to "Automatic associations?", and click OK. 14. From STCAI menu, SmarTeam > Save and select some folder and click OK. 15. From STCAI menu, SmarTeam > LifeCycle > CheckIn(Active Document) 16. Show the profile cards of CATPart and CATIA design table. KO: CATIA design table doesn't have CATIA link TAB. Expected result: SmarTeam Save in CATIA should not be processed in this situation. The user should receive the prompting to do check out/new release of the dependence (Excel) object before saving. .
Local fix
Problem summary
CATIA Link tab isn't displayed for CATIA Design Table when it i s opened as read-only and linked to a CATPart CATIA Link tab isn't displayed for CATIA Design Table when it is opened as read-only and linked to a CATPart Abstract: Customer is able to save a new CATIA document with Microsoft Excel file as design table object which already in Vault (checked in/released). In this case SmarTeam Save operation will successfully processed, but a result will be wrong, because Microsoft Excel object will not be modified and will not take CATIA behavior. Workaround: Perform Check Out/New Release of the Microsoft Excel object before. Scenario: 1. Start SmarTeam Editor and login as joe. 2. Choose some project and select some folder 3. Right-click on the folder and choose Add > CATIA Design Table 5. Then new object Profile Card will open choose DesignTable_test1.xls. as Excel file 6. Check-In the saved object with keep local file 7. Close Editor 8. Start CATIA V5 and SmarTeam > Connect then login as joe. 9. In CATIA session, File > Open and select Part1.CATPart. 10. Click "Design Table" icon then click OK. 11. Select DesignTable_test1.xls under SmarTeam/Work directory. 12. Click Yes to "Automatic associations?", and click OK. 14. From STCAI menu, SmarTeam > Save and select some folder and click OK. 15. From STCAI menu, SmarTeam > LifeCycle > CheckIn(Active Document) 16. Show the profile cards of CATPart and CATIA design table. KO: CATIA design table doesn't have CATIA link TAB. Expected result: SmarTeam Save in CATIA should not be processed in this situation. The user should receive the prompting to do check out/new release of the dependence (Excel) object before saving. .
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN THE DOCUMENTATION DELIVERED WITH SMARTEAM VERSION 5 RELEASE 19 SP03 LEVEL. CATIA User Guide - Info added at the bottom of "Saving a Part" topic, "Viewing CATIA links in a Design Table" section - Promoted to DS .
Temporary fix
Comments
APAR Information
APAR number
HD74383
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
517
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-05-18
Closed date
2008-12-17
Last modified date
2008-12-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
17 December 2008