IBM Support

HD73909: GSD: ERROR DISPLAYED WHEN PERFORMING INTERSECTION WITH TWO CUR VATURE CONTINUITY EXTRAPOLATES.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • GSD:  ERROR DISPLAYED WHEN PERFORMING
    INTERSECTION WITH TWO CURVATURE
    CONTINUITY EXTRAPOLATES.
    .
    SCENARIO.
    1. Start CATIA V5R17 SP08.
    2. Open the CATPart. Workbench- GSD.
    3. Select the Intersection icon.
    4. Select the two Curvature continuity Extrapolate
    features as input.
    5. Click OK.
    6. An error message is displayed and intersection
    is not computed. This is the problem.
    Error: Error displayed when performing intersection
    with two curvature continuity extrapolates.
    .
    .
    

Local fix

Problem summary

  • GSD:  ERROR DISPLAYED WHEN PERFORMING INTERSECTION WITH TWO CUR
    VATURE CONTINUITY EXTRAPOLATES.
    GSD:  ERROR DISPLAYED WHEN PERFORMING
    INTERSECTION WITH TWO CURVATURE
    CONTINUITY EXTRAPOLATES.
    .
    SCENARIO.
    1. Start CATIA V5R17 SP08.
    2. Open the CATPart. Workbench- GSD.
    3. Select the Intersection icon.
    4. Select the two Curvature continuity Extrapolate
    features as input.
    5. Click OK.
    6. An error message is displayed and intersection
    is not computed. This is the problem.
    Error: Error displayed when performing intersection
    with two curvature continuity extrapolates.
    .
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    .
    Incident Diagnosis.
    Intersection gives no result.
    .
    Restriction Explanation.
    Thw two Extrapolates share the same support
    surface. Extrapolate in curvature does not modify
    the support surface. This support surface has only
    one face.
    Hence these support surfaces self intersect each
    other. Self-intersection of surface are not
    computed. It explains why there is no result.
    Intersection between two topologies that share the
    same support surface cannot be done hence an
    error mesage is displayed.
    .
    By-Pass
    Modify the design in order to avoid having the
    same support surface.
    For instance you can do extrapolate in tangency for
    one surface since in this case it gives the same
    shape.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD73909

  • Reported component name

    CATIA V5 SOLARI

  • Reported component ID

    569104000

  • Reported release

    517

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-04-28

  • Closed date

    2008-05-02

  • Last modified date

    2008-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 May 2008