APAR status
Closed as user error.
Error description
PART: MIRROR FAILS WHEN THE PAD IS CREATED WITH REFERENCE LINE DIRECTION. . SCENARIO. 1. Start CATIA V5R18 SP03. 2. Open file TEST.CATPart. 3. Create Pad. During creation of Pad, select Sketch.1 for selection of profile and select Line.1 for reference of direction and specify 100mm for length. 4. Select Pad.1 for Object to mirror and select Plane.2 for Mirroring element. Result A:-Warning message appears. Then click Yes button in Warning message popup window. Message of Update Error appears and mirroring fails. This is the problem. 5. Click cancel and close the Mirror definition dialog box. 6. Delete the Pad and recreate it without the Reference line. 7. Mirror the Pad about Plane.2. The mirror is performed without any error. Error: Mirror fails when the Pad is created with Reference Line direction. . .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Incident Diagnosis. Reference Line is created on YZ plane and Pad is created with this Line as direction. When Mirror of Pad feature is performed, a warning message is thrown which states that the wireframe elements would not be transformed. This implies that the direction of Pad under Mirror would not be transformed. It would still be the same Line. Now, note that Mirroring Plane is created at an angle 45 degrees to YZ plane. When user tries to Mirror Pad feature with respect to this Plane, Pad under Mirror would be created at 45 degrees to the Plane i.e. 90 degrees to YZ plane. This makes the direction of Pad under Mirror parallel to its sketch. This causes an error being thrown "Impossible to compute the geometry" and results in Mirror going into Update error. Hence only at this specific value of mirroring plane angle the mirror fails. . When the user instead of Pad feature selects the Partbody, in this case Mirror command only selects the outer skin of the Current solid and not the only Pad feature. And during any type of transformation when a particular feature is selected its specifications are also taken in account while when complete or current solid is selected then none of the features specifications are taken in account. Hence in this case direction of the Pad is not the Line but it is change to default that is Normal to profile and the mirrored solid is created correctly. . Correct Application. Change the angle for Mirroring Plane and Mirror would work fine. . Documentation Reference. Part Design Getting Started Transformation features . .
APAR Information
APAR number
HD73807
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-04-24
Closed date
2008-04-30
Last modified date
2008-04-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: