Error description
FTA / THE TOLERANCE VALUES DEFINED FOR A DIMENSION STYLE FORMAT ARE OVERWRITTEN WHEN CHANGING THE STYLE . 0. Launch CATIA in admin mode. . 1. Modify a default dimension style within a drafting standard file. . 2. Select Tools > Standards> In the Standard Definition window, and then select Tolerance > Main Value > Format, Lower Numerical Value, and Upper Numerical Value. . 3. Create a custom dimension style within the drafting standard file. While the Standard Definition window is still open, select the dimension style, and click on the ?Create style? button to open the Create style window. In this newly opened window, give the new style a name and ensure that it is duplicated from the default dimension style. . 4. Save these changes by clicking on the ?Save As New? button in the Standard Definition window. and rename this new .XML file. . 5. If necessary move the recently saved drafting standard file to the proper directory where CATIA V5 is instructed to find the drafting standard XML files. . 6. For a given part, activate the FTA Workbench and add Annotation Set.1. Then, make sure that the tolerance standards for Annotation Set.1 are set to ASME_3D_new. . 7. Add dimensions to the part while in the FTA Workbench. Either the Dimension or the Tolerance Advisor tool may be used to create these annotations. Note: make sure the numerical format for these dimensions are set to NUM.DINC in the Numerical Properties toolbar. . 8) Use the Style toolbar to apply a different style to the recently created dimensions. Note: ensure that the numerical format for these dimensions is still set to NUM.DINC in the Numerical Properties toolbar. . RESULTS OBTAINED: After applying styles to an existing dimension, the tolerance values are changed to something other than what was defined in the drafting standard. . EXPECTED RESULTS: . When changing the dimension style for an existing dimension, the displayed tolerance values should reflect the values defined for this new dimension style. For example, if the tolerance values for a dimension style currently being applied are .03, and the tolerance values for the new dimension style are .010, then when this other dimension
Local fix
Problem summary
FTA / THE TOLERANCE VALUES DEFINED FOR A DIMENSION STYLE FORMAT ARE OVERWRITTEN WHEN CHANGING THE STYLE FTA / THE TOLERANCE VALUES DEFINED FOR A DIMENSION STYLE FORMAT ARE OVERWRITTEN WHEN CHANGING THE STYLE . 0. Launch CATIA in admin mode. . 1. Modify a default dimension style within a drafting standard file. . 2. Select Tools > Standards> In the Standard Definition window, and then select Tolerance > Main Value > Format, Lower Numerical Value, and Upper Numerical Value. . 3. Create a custom dimension style within the drafting standard file. While the Standard Definition window is still open, select the dimension style, and click on the ?Create style? button to open the Create style window. In this newly opened window, give the new style a name and ensure that it is duplicated from the default dimension style. . 4. Save these changes by clicking on the ?Save As New? button in the Standard Definition window. and rename this new .XML file. . 5. If necessary move the recently saved drafting standard file to the proper directory where CATIA V5 is instructed to find the drafting standard XML files. . 6. For a given part, activate the FTA Workbench and add Annotation Set.1. Then, make sure that the tolerance standards for Annotation Set.1 are set to ASME_3D_new. . 7. Add dimensions to the part while in the FTA Workbench. Either the Dimension or the Tolerance Advisor tool may be used to create these annotations. Note: make sure the numerical format for these dimensions are set to NUM.DINC in the Numerical Properties toolbar. . 8) Use the Style toolbar to apply a different style to the recently created dimensions. Note: ensure that the numerical format for these dimensions is still set to NUM.DINC in the Numerical Properties toolbar. . RESULTS OBTAINED: After applying styles to an existing dimension, the tolerance values are changed to something other than what was defined in the drafting standard. . EXPECTED RESULTS: . When changing the dimension style for an existing dimension, the displayed tolerance values should reflect the values defined for this new dimension style. For example, if the tolerance values for a dimension style currently being applied are .03, and the tolerance values for the new dimension style are .010, then when this other dimension style is applied the dimension should be displayed with tolerance values of .010. . ADDITIONAL INFORMATION: When reviewing the tolerance values in the Properties window, the two place tolerance standard value (i.e. .03) has been converted to .00118 (≈.03/25.4), and the three place tolerance standard value (i.e. .010) has been converted to .000394 (≈.010/25.4). Note: .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5R20 GA LEVEL. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19SP01. INCIDENT DIAGNOSIS: . FTA / THE TOLERANCE VALUES DEFINED FOR A DIMENSION STYLE FORMAT ARE OVERWRITTEN WHEN CHANGING THE STYLE. . CORRECTION EXPLANATION: . The correction has been done for the Standards editor for the Tolerance > Upper/Lower Numerical Values. . Now the behavior is correct. The behavior can be described well by the avi file. So to get the correct results. Please follow the following steps: 1. Go to Tools/ Options/General/Parameters and measure tool/ Units/ Change the Unit of length to "Inch". 2. In Tools/ Standard/Drafting /Style : Length distance Dimension/ : Update the : Tolerance > Main Value > Lower Numerical Value, and Upper Numerical Value. . Please note that the "in" is being specified now. Save the changes made to the New XML file. . Please see the attached avi file. . BYPASS: To get the correct results use the values in "mm" or in "degrees". .
Temporary fix
Comments
APAR Information
APAR number
HD73565
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-04-16
Closed date
2008-06-24
Last modified date
2008-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP