HD71960: ASD : UPDATE : CAPART CANNOT BE UPDATED WHEN UPDATE ICON IS CLI CKED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ASD : UPDATE : CAPART CANNOT BE UPDATED
    WHEN UPDATE ICON IS CLICKED
    .
    SCENARIO:
    1. Open supplied CATProduct in ASD workbench.
    2. Click on Update All icon.
    3. Expand LB5921_CalculGen(CalculGen) in
    specification tree
    4. Double click on LB5921_CalculGen in
    specification tree. Part Design workbench appears
    5. Click on Update All icon
    .
    OBSERVATION:
    CATPart is neither updated no any error message
    is displayed
    .
    

Local fix

Problem summary

  • ASD : UPDATE : CAPART CANNOT BE UPDATED WHEN UPDATE ICON IS CLI
    CKED
    ASD : UPDATE : CAPART CANNOT BE UPDATED
    WHEN UPDATE ICON IS CLICKED
    .
    SCENARIO:
    1. Open supplied CATProduct in ASD workbench.
    2. Click on Update All icon.
    3. Expand LB5921_CalculGen(CalculGen) in
    specification tree
    4. Double click on LB5921_CalculGen in
    specification tree. Part Design workbench appears
    5. Click on Update All icon
    .
    OBSERVATION:
    CATPart is neither updated no any error message
    is displayed
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    Incident Diagnosis
    The reaction located in the CATPart reacts to the
    update of the CATPart. This reaction computes the
    value of parameter (located in ParameterSet).
    This parameter is an input to rule that is in input of
    the part.
    .
    Restriction Explanation
    The modification of the parameter impacts the part
    through the rule. On R17 level, the reaction was
    not working at all and hence the parameter was not
    correctly computed.
    By-Pass
    The reaction should react to another event. Or the
    rule must not be integrated to the part update.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD71960

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-02-28

  • Closed date

    2008-03-14

  • Last modified date

    2008-03-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: