IBM Support

HD71748: DELETING/CUTTING INSTANCE BELOW INSTANCE OF PROD SPEC. DOES NOT SAVE TO ENOVIA.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • DELETING/CUTTING INSTANCE BELOW INSTANCE
    OF PROD SPEC. DOES NOT SAVE TO ENOVIA.
    .
    SCENARIO:
    1) Create a product and associate an action to the
    product.
    2) Create Product Specification with instance in
    Enovia.
    3) Insert Product specification below the product
    created at step 1.
    4) Expand the structure and select instance below
    product specification.
    5) Send the instance to CATIA.
    6)  In CATIA, delete or cut the instance from below
    the instance of the product specification.
    7) Save to ENOVIA.
    8)  In ENOVIA, refresh the product editor.
    9) Select the instance that was deleted.
    10) Select the Configuration tab on the property
    card.
    .
    Error - There is no Cut operation from the delete in
    CATIA applied to the instance.
    .
    Expected Result: There would be a Cut operation.
    .
    User expectation is that an unsolved cut operation
    would be applied to the instance, regardless of an
    action being associated to the product editor
    session. Reason behind his preference is that user
    do not want any system generated modification to
    be created and linked to the action.
    .
    

Local fix

Problem summary

  • DELETING/CUTTING INSTANCE BELOW INSTANCE OF PROD SPEC. DOES NOT
    SAVE TO ENOVIA.
    DELETING/CUTTING INSTANCE BELOW INSTANCE
    OF PROD SPEC. DOES NOT SAVE TO ENOVIA.
    .
    SCENARIO:
    1) Create a product and associate an action to the
    product.
    2) Create Product Specification with instance in
    Enovia.
    3) Insert Product specification below the product
    created at step 1.
    4) Expand the structure and select instance below
    product specification.
    5) Send the instance to CATIA.
    6)  In CATIA, delete or cut the instance from below
    the instance of the product specification.
    7) Save to ENOVIA.
    8)  In ENOVIA, refresh the product editor.
    9) Select the instance that was deleted.
    10) Select the Configuration tab on the property
    card.
    .
    Error - There is no Cut operation from the delete in
    CATIA applied to the instance.
    .
    Expected Result: There would be a Cut operation.
    .
    User expectation is that an unsolved cut operation
    would be applied to the instance, regardless of an
    action being associated to the product editor
    session. Reason behind his preference is that user
    do not want any system generated modification to
    be created and linked to the action.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    ENOVIA.
    Restriction Explanation -
    When a prod spec is instantiated under some PRC
    as product instance, te item instance under this
    Prod Spec becomes a Tempo II. This Tempo II
    does not have its own effectivity and when its
    parent PSpec's effectivity will be resolved, it will be
    carried over to this tempo ii. Also when an action is
    associated to the product editor session, there will
    be no system generated mods for these tempo ii's
    as the tempo ii dont have its own effectivity and no
    such operation is allowed on tempo ii. When the
    user Cuts/deletes the tempo ii through catia and
    saves it back to Enovia, then this operation wont be
    seen on the tempo ii. Although if the real ii is
    opened, this particular operation will be visible to
    us. To add to it, even if the effectivity of any real ii
    under the prod spec was earlier resolved, still it
    wont be shown in case of tempo ii. So therefore
    even the cut operation performed through catia,
    will not be seen in case of tempo II and the system
    generated mod wont be getting created for tempo
    ii.
    =================================
    By-Pass -
    The user can check the cut/delete operation by
    checking the config tab of the real ii i.e. under the
    parent prod spec where the ii was actually
    instantiated but not under the PRC where this prod
    spec is instantiated as Product instance.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD71748

  • Reported component name

    ENOVIA LCA NT>X

  • Reported component ID

    569151700

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-02-20

  • Closed date

    2008-03-20

  • Last modified date