APAR status
Closed as Permanent restriction.
Error description
DELETING/CUTTING INSTANCE BELOW INSTANCE OF PROD SPEC. DOES NOT SAVE TO ENOVIA. . SCENARIO: 1) Create a product and associate an action to the product. 2) Create Product Specification with instance in Enovia. 3) Insert Product specification below the product created at step 1. 4) Expand the structure and select instance below product specification. 5) Send the instance to CATIA. 6) In CATIA, delete or cut the instance from below the instance of the product specification. 7) Save to ENOVIA. 8) In ENOVIA, refresh the product editor. 9) Select the instance that was deleted. 10) Select the Configuration tab on the property card. . Error - There is no Cut operation from the delete in CATIA applied to the instance. . Expected Result: There would be a Cut operation. . User expectation is that an unsolved cut operation would be applied to the instance, regardless of an action being associated to the product editor session. Reason behind his preference is that user do not want any system generated modification to be created and linked to the action. .
Local fix
Problem summary
DELETING/CUTTING INSTANCE BELOW INSTANCE OF PROD SPEC. DOES NOT SAVE TO ENOVIA. DELETING/CUTTING INSTANCE BELOW INSTANCE OF PROD SPEC. DOES NOT SAVE TO ENOVIA. . SCENARIO: 1) Create a product and associate an action to the product. 2) Create Product Specification with instance in Enovia. 3) Insert Product specification below the product created at step 1. 4) Expand the structure and select instance below product specification. 5) Send the instance to CATIA. 6) In CATIA, delete or cut the instance from below the instance of the product specification. 7) Save to ENOVIA. 8) In ENOVIA, refresh the product editor. 9) Select the instance that was deleted. 10) Select the Configuration tab on the property card. . Error - There is no Cut operation from the delete in CATIA applied to the instance. . Expected Result: There would be a Cut operation. . User expectation is that an unsolved cut operation would be applied to the instance, regardless of an action being associated to the product editor session. Reason behind his preference is that user do not want any system generated modification to be created and linked to the action. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN ENOVIA. Restriction Explanation - When a prod spec is instantiated under some PRC as product instance, te item instance under this Prod Spec becomes a Tempo II. This Tempo II does not have its own effectivity and when its parent PSpec's effectivity will be resolved, it will be carried over to this tempo ii. Also when an action is associated to the product editor session, there will be no system generated mods for these tempo ii's as the tempo ii dont have its own effectivity and no such operation is allowed on tempo ii. When the user Cuts/deletes the tempo ii through catia and saves it back to Enovia, then this operation wont be seen on the tempo ii. Although if the real ii is opened, this particular operation will be visible to us. To add to it, even if the effectivity of any real ii under the prod spec was earlier resolved, still it wont be shown in case of tempo ii. So therefore even the cut operation performed through catia, will not be seen in case of tempo II and the system generated mod wont be getting created for tempo ii. ================================= By-Pass - The user can check the cut/delete operation by checking the config tab of the real ii i.e. under the parent prod spec where the ii was actually instantiated but not under the PRC where this prod spec is instantiated as Product instance. .
Temporary fix
Comments
APAR Information
APAR number
HD71748
Reported component name
ENOVIA LCA NT>X
Reported component ID
569151700
Reported release
518
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-02-20
Closed date
2008-03-20
Last modified date
2008-03-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDJRN","label":"ENOVIA LCA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
20 March 2008