IBM Support

HD71742: CATIA V5 DRAFTING ERROR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • CATIA V5 Drafting error
    SCENARIO:
    1. Open the provided CATPart and CATDrawing
    with V5R19GA.
    2. In the CATDrawing, double click the callout
    arrow AA and invert the arrow direction by
    selecting Invert Profile Direction button.
    3. Select End Profile Edition.
    Result:
    Error : Intersection computation has failed appears
    and a red cross appears in the section view. The
    section view disappears and only the centre lines
    remain in the view.
    .
    

Local fix

Problem summary

  • CATIA V5 Drafting error
    CATIA V5 Drafting error
    SCENARIO:
    1. Open the provided CATPart and CATDrawing
    with V5R19GA.
    2. In the CATDrawing, double click the callout
    arrow AA and invert the arrow direction by
    selecting Invert Profile Direction button.
    3. Select End Profile Edition.
    Result:
    Error : Intersection computation has failed appears
    and a red cross appears in the section view. The
    section view disappears and only the centre lines
    remain in the view.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    RESTRICTION EXPLANATION:
    The solid.1 in remove.2 has tangential faces with
    the partbody which cases the boolean operation
    between the remove.2 and partbody to fail. In
    CATIA V5 such kind of tangential faces are not
    allowed between the bodies involved in the boolean
    operation.
    .
    BYPASS:
    Extend the face of Solid.1 using Thickness
    operation. After this operation the section view is
    displayed correctly even after changing the callout
    direction.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD71742

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-02-20

  • Closed date

    2008-03-12

  • Last modified date

    2008-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 March 2008