APAR status
Closed as unreproducible in next release.
Error description
Scenario : 1. Start VPM through Startcenter. 2. Launch CATIA V5 through VPM with Electrical Piping and Tubing Settings 3. Create a new CATProduct using "Electrical Harness Assembly" workbench. 4. Convert the CATProduct into "Geometrical Bundle" 5. Using catalog browser insert/instantiate two connectors (CATParts) from existing catalog in VPM (Connectors must have electrical attributes attached to it : "Bundle Connection Point") 6. Using "Smart Place", place the two connectors in space apart from each other by 150 mm approximately. 7. Create a new Multibranchable CATPart document, underneath of the same CATProduct 8. Using the "Route Definition" as shown in the picture at right route a branch/bundle segment between the two connectors. 9. Click "OK" to complete the "Route Definition". The "Route Definition" window will close. 10. Double click on Multibranchable CATPart created in step 6 above to make it active. 11. In VPM panel, select the environment as "SUBCOMP", and make sure you have Object = DOCUMENT. 12. Click on the green 'Create and Save' icon a. "Create and Save" dialog box will appear, as shown in the picture at right b. Enter all the fields and click on the field box "Source" another window will pop up then click "Save as New Document". And select "Keep Modified". c. All the Fields should show Green box with tick mark on it. d. Click OK to finish, a separate window of "Confirm write?" appears as shown on right side. Click YES to finish. 13. A new Part/Document "S320DCAGBN2" will get stored in SUBCOMP environment. 14. Repeat step 12 and 13 to "Create and Save" the CATProduct created in step 1 above, with part number, description as given below and other details remaining same as in the picture at right. PART NUMBER = "S320DCAGBN2" SUB COMP = "S320DCAGBN2" TYPE = CATProduct DESCRIPTION= GBN Power Locks CATIA V5 Session behavior inside Source = "Replace by target" 15. A new Part named as "S320DCAGBN2" will get stored in SUBCOMP environment. 16. Since the connectors are instantiated from VPM catalog, there is no need to save these connectors. 17. Close the CATProduct file. 18. Repeat the steps from 1 to 16 to create another set of CATProduct and CATPart with following attributes CATPart PART NUMBER = "S320DCAGBN1" SUB COMP = "S320DCAGBN1A" DESCRIPTION= BASE BUNDLE TYPE= CATPART CATIA V5 Session behavior inside Source = "Keep Modified" CATProduct PART NUMBER = "S320DCAGBN1" SUB COMP = "S320DCAGBN1" DESCRIPTION = BASE BUNDLE TYPE = CATPRODUCT CATIA V5 Session behavior inside Source = "Replace by target" 19. Close the CATProduct file. 20. From VPMA window load the CATProduct document "S320DCAGBN2" in CATIA V5 21. While the CATProduct document S320DCAGBN2 is opened in CATIA V5, load another CATProduct document "S320DCAGBN1" from VPMA panel Problem : CATIA session hangs. .
Local fix
Problem summary
Interop VPM CATIA V5 Session hangs while loading two Electrical GeometricalBundleCATProducts in the same CATIA session Scenario : 1. Start VPM through Startcenter. 2. Launch CATIA V5 through VPM with Electrical Piping and Tubing Settings 3. Create a new CATProduct using "Electrical Harness Assembly" workbench. 4. Convert the CATProduct into "Geometrical Bundle" 5. Using catalog browser insert/instantiate two connectors (CATParts) from existing catalog in VPM (Connectors must have electrical attributes attached to it : "Bundle Connection Point") 6. Using "Smart Place", place the two connectors in space apart from each other by 150mm approximately. 7. Create a new Multibranchable CATPart document, underneath of the same CATProduct 8. Using the "Route Definition" as shown in the picture at right route a branch/bundle segment between the two connectors. 9. Click "OK" to complete the "Route Definition". The "Route Definition" window will close. 10. Double click on Multibranchable CATPart created in step 6 above to make it active. 11. In VPM panel, select the environment as "SUBCOMP", and make sure you have Object = DOCUMENT. 12. Click on the green 'Create and Save' icon a. "Create and Save" dialog box will appear, as shown in the picture at right b. Enter all the fields and click on the field box "Source" another window will pop up then click "Save as New Document". And select "Keep Modified". c. All the Fields should show Green box with tick mark on it. d. Click OK to finish, a separate window of "Confirm write?" appears as shown on right side. Click YES to finish. 13. A new Part/ Document "S320DCAGBN2" will get stored in SUBCOMP environment. 14. Repeat step 12 and 13 to "Create and Save" the CATProduct created in step1 above, with part number, description as given below and other details remaining same as in the picture at right. PART NUMBER = "S320DCAGBN2" SUB COMP = "S320DCAGBN2" TYPE = CATProduct DESCRIPTION= GBN Power Locks CATIA V5 Session behavior inside Source = "Replace by target" 15. A new Part named as "S320DCAGBN2" will get stored in SUBCOMP environment. 16. Since the connectors are instantiated from VPM catalog, there is no need to save these connectors. 17. Close the CATProduct file. 18. Repeat the steps from 1 to 16 to create another set of CATProduct and CATPart with following attributes CATPart PART NUMBER = "S320DCAGBN1" SUB COMP = "S320DCAGBN1A" DESCRIPTION= BASE BUNDLE TYPE= CATPART CATIA V5 Session behavior inside Source = "Keep Modified" CATProduct PART NUMBER = "S320DCAGBN1" SUB COMP = "S320DCAGBN1" DESCRIPTION = BASE BUNDLE TYPE = CATPRODUCT CATIA V5 Session behavior inside Source = "Replace by target" 19. Close the CATProduct file. 20. From VPMA window load the CATProduct document "S320DCAGBN2" in CATIA V5 21. While the CATProduct document S320DCAGBN2 is opened in CATIA V5, load another CATProduct document "S320DCAGBN1" from VPMA panel Problem : CATIA session hangs. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 16. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 19 GA level AND ON V5R17SP08 AND V5R18SP03 Incident Diagnosis Session hangs while loading two Electrical Geometrical Bundle CATProducts in the same CATIA session. Reason This problem does not occur on V5R17 SP8, V5R18 SP3 and V5R19ga. .
APAR Information
APAR number
HD68486
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
516
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-10-22
Closed date
2007-12-12
Last modified date
2008-01-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 HP-UX
Fixed component ID
569102000
Applicable component levels
R518 PSN SP51803
UP08/01/25 I 1000
R517 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 January 2008