HD68486: INTEROP VPM CATIA V5 SESSION HANGS WHILE LOADING TWO ELECTRICAL GEOMETRICAL BUNDLE CATPRODUCTS IN THE SAME CATIA SESSION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • Scenario :
    1. Start VPM through Startcenter.
    2. Launch CATIA V5 through VPM with Electrical Piping and
       Tubing Settings
    3. Create a new CATProduct using "Electrical Harness Assembly"
       workbench.
    4. Convert the CATProduct into "Geometrical Bundle"
    5. Using catalog browser insert/instantiate two connectors
       (CATParts) from existing catalog in VPM (Connectors must
       have electrical attributes attached to it : "Bundle
       Connection Point")
    6. Using "Smart Place", place the two connectors in space apart
       from each other by 150 mm approximately.
    7. Create a new Multibranchable CATPart document, underneath of
       the same CATProduct
    8. Using the "Route Definition" as shown in the picture at
       right route a branch/bundle segment between the two
       connectors.
    9. Click "OK" to complete the "Route Definition".
       The "Route Definition" window will close.
    10. Double click on Multibranchable CATPart created in step 6
        above to make it active.
    11. In VPM panel, select the environment as "SUBCOMP", and make
        sure you have Object = DOCUMENT.
    12. Click on the green 'Create and Save' icon
       a. "Create and Save" dialog box will appear, as shown in the
          picture at right
       b. Enter all the fields and click on the field box "Source"
          another window will pop up then click "Save as New
          Document".  And select "Keep Modified".
       c. All the Fields should show Green box with tick mark on it.
       d. Click OK to finish, a separate window of "Confirm write?"
          appears as shown on right side.  Click YES to finish.
    13. A new Part/Document "S320DCAGBN2" will get stored in
        SUBCOMP environment.
    14. Repeat step 12 and 13 to "Create and Save" the CATProduct
        created in step 1 above, with part number, description as
        given below and other details remaining same as in the
        picture at right.  PART NUMBER = "S320DCAGBN2"
        SUB COMP = "S320DCAGBN2"
        TYPE = CATProduct
        DESCRIPTION= GBN Power Locks
        CATIA V5 Session behavior inside Source = "Replace by
        target"
    15. A new Part named as "S320DCAGBN2" will get stored in
        SUBCOMP environment.
    16. Since the connectors are instantiated from VPM catalog,
        there is no need to save these connectors.
    17. Close the CATProduct file.
    18. Repeat the steps from 1 to 16 to create another set of
        CATProduct and CATPart with following attributes CATPart
        PART NUMBER = "S320DCAGBN1"
        SUB COMP = "S320DCAGBN1A"
        DESCRIPTION= BASE BUNDLE
        TYPE= CATPART
        CATIA V5 Session behavior inside Source = "Keep Modified"
        CATProduct
        PART NUMBER = "S320DCAGBN1"
        SUB COMP = "S320DCAGBN1"
        DESCRIPTION = BASE BUNDLE
        TYPE = CATPRODUCT
        CATIA V5 Session behavior inside Source = "Replace by
        target"
    19. Close the CATProduct file.
    20. From VPMA window load the CATProduct document "S320DCAGBN2"
        in CATIA V5
    21. While the CATProduct document S320DCAGBN2 is opened in
        CATIA V5, load another CATProduct document "S320DCAGBN1"
        from VPMA panel Problem : CATIA session hangs.
    .
    

Local fix

Problem summary

  • Interop VPM CATIA V5 Session hangs while loading two Electrical
    GeometricalBundleCATProducts in the same CATIA session
    Scenario :
    1. Start VPM through Startcenter.
    2. Launch CATIA V5 through VPM with Electrical
    Piping and Tubing Settings
    3. Create a new CATProduct using "Electrical
    Harness Assembly" workbench.
    4. Convert the CATProduct into "Geometrical
    Bundle"
    5. Using catalog browser insert/instantiate two
    connectors (CATParts) from existing catalog in VPM
    (Connectors must have electrical attributes
    attached to it : "Bundle Connection Point")
    6. Using "Smart Place", place the two connectors in
    space apart from each other by 150mm
    approximately.
    7. Create a new Multibranchable CATPart
    document, underneath of the same CATProduct
    8. Using the "Route Definition" as shown in the
    picture at right route a branch/bundle segment
    between the two connectors.
    9. Click "OK" to complete the "Route Definition".
    The "Route Definition" window will close.
    10. Double click on Multibranchable CATPart
    created in step 6 above to make it active.
    11. In VPM panel, select the environment
    as "SUBCOMP", and make sure you have Object =
    DOCUMENT.
    12. Click on the green 'Create and Save' icon
    a. "Create and Save" dialog box will appear, as
    shown in the picture at right
    b. Enter all the fields and click on the field
    box "Source" another window will pop up then
    click "Save as New Document".
    And select "Keep Modified".
    c. All the Fields should show Green box with tick
    mark on it.
    d. Click OK to finish, a separate window
    of "Confirm write?" appears as shown on right side.
    Click YES to finish.
    13. A new Part/ Document "S320DCAGBN2" will get
    stored in SUBCOMP environment.
    14. Repeat step 12 and 13 to "Create and Save"
    the CATProduct created in step1 above, with part
    number, description as given below and other
    details remaining same as in the picture at right.
    PART NUMBER = "S320DCAGBN2"
    SUB COMP = "S320DCAGBN2"
    TYPE = CATProduct
    DESCRIPTION= GBN Power Locks
    CATIA V5 Session behavior inside Source
    = "Replace by target"
    15. A new Part named as "S320DCAGBN2" will get
    stored in SUBCOMP environment.
    16. Since the connectors are instantiated from VPM
    catalog, there is no need to save these connectors.
    17. Close the CATProduct file.
    18. Repeat the steps from 1 to 16 to create another
    set of CATProduct and CATPart with following
    attributes
    CATPart
    PART NUMBER = "S320DCAGBN1"
    SUB COMP = "S320DCAGBN1A"
    DESCRIPTION= BASE BUNDLE
    TYPE= CATPART
    CATIA V5 Session behavior inside Source = "Keep
    Modified"
    CATProduct
    PART NUMBER = "S320DCAGBN1"
    SUB COMP = "S320DCAGBN1"
    DESCRIPTION = BASE BUNDLE
    TYPE = CATPRODUCT
    CATIA V5 Session behavior inside Source
    = "Replace by target"
    19. Close the CATProduct file.
    20. From VPMA window load the CATProduct
    document "S320DCAGBN2" in CATIA V5
    21. While the CATProduct document
    S320DCAGBN2 is opened in CATIA V5,
    load another CATProduct
    document "S320DCAGBN1" from VPMA panel
    Problem :
    CATIA session hangs.
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 16.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    CATIA VERSION 5 RELEASE 19 GA level AND ON
    V5R17SP08 AND V5R18SP03
    Incident Diagnosis
    Session hangs while loading two Electrical
    Geometrical Bundle CATProducts in the same
    CATIA session.
    Reason
    This problem does not occur on V5R17 SP8, V5R18
    SP3 and V5R19ga.
    .
    

APAR Information

  • APAR number

    HD68486

  • Reported component name

    CATIA V5 HP-UX

  • Reported component ID

    569102000

  • Reported release

    516

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-10-22

  • Closed date

    2007-12-12

  • Last modified date

    2008-01-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 HP-UX

  • Fixed component ID

    569102000

Applicable component levels

  • R518 PSN SP51803

       UP08/01/25 I 1000

  • R517 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
25 January 2008