Error description
ASD : SECTION WITH VOLUME CUT IS NOT FILLED. Scenario. . 1. Tools/Options/Mechanical Design/Assembly Design/tab DMU-Sectioning -> deactivate "Allow measures on a section created with a simple plane" 2. Load the CATProduct. 3. Double click on "Section.1" in the specification tree (under Applications and Sections). 4. Activate 'Volume Cut' in Sectioning Definition window . Expected Result . Section should be shown filled. .
Local fix
Problem summary
ASD : SECTION WITH VOLUME CUT IS NOT FILLED. ASD : SECTION WITH VOLUME CUT IS NOT FILLED. Scenario. . 1. Tools/Options/Mechanical Design/Assembly Design/tab DMU-Sectioning -> deactivate "Allow measures on a section created with a simple plane" 2. Load the CATProduct. 3. Double click on "Section.1" in the specification tree (under Applications and Sections). 4. Activate 'Volume Cut' in Sectioning Definition window . Expected Result . Section should be shown filled. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA . Incident Diagnosis. . A section with volume cut is not shown filled. . Restriction Explanation. . User selects the plane by choosing geometrical target - XY Plane( which is at X=0,Y=0,Z=0), at this selection, the section plane cuts exactly at the frontier of the Pad feature which represents a cylinder. To create a filled section, a closed contour is needed and then it is filled to show a volume cut. In this particular case, a section polyline result a mix between intersection of section plane and Pad1 feature , and sectionplane and Pad2 feature. Hence a single closed contour is NOT obtained which can be used to fill and show the result and hence user sees the section as NOT filled. Also it is NOT possible to identify a single contour from two contours , which can be closed . It is because of performance reason. . Bypass User can position the section plane by using Z- normal. When user selection is Z-normal then the section plane is not positioned at X=0,Y=0 and Z=0. Hence user will get a section which has closed contour and thus showing the filled section. .
Temporary fix
Comments
APAR Information
APAR number
HD68329
Reported component name
CATIA V5 HP-UX
Reported component ID
569102000
Reported release
516
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-10-17
Closed date
2007-12-14
Last modified date
2007-12-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
14 December 2007