HD66985: DRAFTING (GENDRAFT) / ON UPDATING A CATDRAWING, CATIA V5 GOES I NTO A LOOP.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Drafting (GenDraft) / On updating a CATDrawing,
    CATIA V5 goes into a loop.
    .
    SCENARIO:
    .
    Customized settings are used.
    .
    1. A CATDrawing is created for a CATProduct.
    2. The CATProduct is switched to Design Mode and
    the CATDrawing is updated using Force Update
    command. Update is correct.
    3. Now both the CATDrawing and the CATProduct
    are closed without saving.
    4. The CATDrawing is reopened and updated using
    the Force Update command.
    .
    OBSERVATION:
    .
    On updating a CATDrawing, CATIA goes into a loop.
    .
    EXPECTED RESULT:
    .
    CATIA should not go into a loop on updating the
    CATDrawing.
    .
    

Local fix

Problem summary

  • Drafting (GenDraft) / On updating a CATDrawing, CATIA V5 goes i
    nto a loop.
    Drafting (GenDraft) / On updating a CATDrawing,
    CATIA V5 goes into a loop.
    .
    SCENARIO:
    .
    Customized settings are used.
    .
    1. A CATDrawing is created for a CATProduct.
    2. The CATProduct is switched to Design Mode and
    the CATDrawing is updated using Force Update
    command. Update is correct.
    3. Now both the CATDrawing and the CATProduct
    are closed without saving.
    4. The CATDrawing is reopened and updated using
    the Force Update command.
    .
    OBSERVATION:
    .
    On updating a CATDrawing, CATIA goes into a loop.
    .
    EXPECTED RESULT:
    .
    CATIA should not go into a loop on updating the
    CATDrawing.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP02.
    .
    INCIDENT DIAGNOSIS:
    .
    Drafting (GenDraft) / On updating a CATDrawing,
    CATIA V5 goes into a loop.
    .
    CORRECTION EXPLANATION:
    .
    The problem has been corrected. There is no more
    cpu loop when updating the drawing.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD66985

  • Reported component name

    CATIA V5 HP-UX

  • Reported component ID

    569102000

  • Reported release

    518

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-08-28

  • Closed date

    2007-09-21

  • Last modified date

    2007-11-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 HP-UX

  • Fixed component ID

    569102000

Applicable component levels

  • R518 PSN SP51802

       UP07/11/13 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
13 November 2007