APAR status
Closed as user error.
Error description
Machining (3ASMG) - Machine simulation cannot reach a point then it should Scenario: 1 - Run CATIA V5 R17 2 - Load the provided CATProcess 3 - Select the Machining Operation named "Multi- Axis Sweeping.3" (under PO2: 5 axis machine / 01 sweeping). 4 - In contextual menu, click on "replay tool path". 5 - In the window, click on "Machine tool path simulation". Problem: A warning message appears in a window and tell us "some points of the tool path of the activity <....> Unreachable. They cannot be simulated". .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
Incident Diagnosis Machine simulation cannot reach a point then it should . Correct Application The modeled 5-X machine has implicit limits on its reachability. For the unreachable point P6 values of i, j, k values are 0.06388, -0.01775, 0.997799 . Please note that the value of k here is greater than 0.9962, making it unreachable . Documentation Reference NC Machine Tool Builder User Tasks .
APAR Information
APAR number
HD66292
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-07-26
Closed date
2007-09-07
Last modified date
2007-09-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
07 September 2007