Error description

  • Preparation:
    1) Copy the Test1 Folder just under C drive
    2) Start CATIA R17SP3HF17.
    3) Tools / option / General / Document
    Please change Linked Document Localization in the
    following order:
    .
    Folder of the pointing document
    Relative folder
    Folder of the link
    Other folders
    Catalog & startup documents
    Entreprise Process-libraries
    IPD
    ENOVIA LCA
    ENOVIA VPM database
    SmarTeam
    .
    4) Tools / option / Infrastructure / Product
    Structure / Cache Management
    Work with the cache system: Active
    5) Close CATIA
    .
    Scenario:
    1) Start CATIA R17SP3HF17
    2) File / Open AAA.CATProduct
    Workbench : Product Structure
    3) File / Desk
    4) Right click BBB.CATPart
    5) Click Load
    -> BBB.CATPart
    6) Repeat Process 4) to 5) for CCC.CATPart
    -> CCC.CATPart is loaded
    7) Close Desk Window
    8) Right click CCC(Part2.1) in tree
    -> Context menu is displayed
    9) Click Part2.1 Object / Open in New Window
    -> CCC.CATPart' is opened
    10) File / Save as and save CCC.CATPart in Test2
    folder (Test2 folder is in Test1 folder)
    -> Save As dialog box is opened
    11) Click Yes in Message box
    12) File / Save Management
    13) Check the Location of CCC.CATPart
    ->  It is OK if saved in Test2 folder
    14) Click Cancel
    15) Right click BBB(Part1.1) in tree
    -> Context menu is displayed
    16) Click to Representations / Visualization Mode
    -> BBB(Part1.1) is changed to Visualization Mode
    17) File / Close CCC.CATPart
    Repeat 15) to 16) for CCC(Part2.1)
    -> CCC(Part1.1) is changed to Visualization Mode
    18) File / Save Management
    19) Click to AAA.CATProduct
    20) Click Save
    21) Click OK
    22) Close AAA.CATProduct
    23) Open Test 1 folder
    24) Delete CCC.CATPart which is just under Test1
    25) File / Open AAA.CATProduct
    -> The following message is displayed:
    .
    Open
    The files in the following list could not be found or
    contain the wrong information for the active
    document.
    C:/Test1/CCC.CATPart
    .
    Expected Result
    The link of CCC.CATPart should be CCC.CATPart
    in Test2 folder.
    .
    

Local fix

Problem summary

  • FILE / OPEN CATPRODUCT : PB LOCATING A CATPART SAVED WITH CACHE
    ACTIVE AND SPECIFIC DOCUMENT LOCALIZATION OPTIONS
    Preparation:
    1) Copy the Test1 Folder just under C drive
    2) Start CATIA R17SP3HF17.
    3) Tools / option / General / Document
    Please change Linked Document Localization in the
    following order:
    .
    Folder of the pointing document
    Relative folder
    Folder of the link
    Other folders
    Catalog & startup documents
    Entreprise Process-libraries
    IPD
    ENOVIA LCA
    ENOVIA VPM database
    SmarTeam
    .
    4) Tools / option / Infrastructure / Product
    Structure / Cache Management
    Work with the cache system: Active
    5) Close CATIA
    .
    Scenario:
    1) Start CATIA R17SP3HF17
    2) File / Open AAA.CATProduct
    Workbench : Product Structure
    3) File / Desk
    4) Right click BBB.CATPart
    5) Click Load
    -> BBB.CATPart
    6) Repeat Process 4) to 5) for CCC.CATPart
    -> CCC.CATPart is loaded
    7) Close Desk Window
    8) Right click CCC(Part2.1) in tree
    -> Context menu is displayed
    9) Click Part2.1 Object / Open in New Window
    -> CCC.CATPart' is opened
    10) File / Save as and save CCC.CATPart in Test2
    folder (Test2 folder is in Test1 folder)
    -> Save As dialog box is opened
    11) Click Yes in Message box
    12) File / Save Management
    13) Check the Location of CCC.CATPart
    ->  It is OK if saved in Test2 folder
    14) Click Cancel
    15) Right click BBB(Part1.1) in tree
    -> Context menu is displayed
    16) Click to Representations / Visualization Mode
    -> BBB(Part1.1) is changed to Visualization Mode
    17) File / Close CCC.CATPart
    Repeat 15) to 16) for CCC(Part2.1)
    -> CCC(Part1.1) is changed to Visualization Mode
    18) File / Save Management
    19) Click to AAA.CATProduct
    20) Click Save
    21) Click OK
    22) Close AAA.CATProduct
    23) Open Test 1 folder
    24) Delete CCC.CATPart which is just under Test1
    25) File / Open AAA.CATProduct
    -> The following message is displayed:
    .
    Open
    The files in the following list could not be found or
    contain the wrong information for the active
    document.
    C:/Test1/CCC.CATPart
    .
    Expected Result
    The link of CCC.CATPart should be CCC.CATPart
    in Test2 folder.
    .
    

Problem conclusion

  • null
    ==========*===========*==========
    When the pointed part is unloaded (switched into
    visu mode) the link from the product to this part
    is rerouted onto the original part on disk.
    .
    The document localization strategies that are set
    by the user through Tools/Option/Document are
    used to search the pointed document on disk again
    when it is unloaded.
    The Folder of the pointing document is on the top of
    the Linked Document Localization list so the part is
    searched in the folder of the product first, and the
    original part is found.
    .
    Bypass:
    Remove the part may be removed on disk before
    the switch into visu mode.
    .
    THIS PROBLEM IS A PERMANENT RESTRICTION.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD64885

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-06-06

  • Closed date

    2007-06-29

  • Last modified date

    2007-06-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
29 June 2007