HD64390: PART: BOOLEAN - NON-MANIFOLD EDGES CREATED DURING BOOLEAN OPERA TION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • PART: BOOLEAN - NON-MANIFOLD EDGES
    CREATED DURING BOOLEAN OPERATION.
    .
    SCENARIO:
    0. Start CATIA.
    1. Open the file: "9534.CATPart". Workbench: "Part
    Design".
    2. Select "Body.2" with context menu "Body.2
    object"/ "Remove". Incident report is displayed:
    Non manifold edges have been created during
    boolean operation. Non manifold edges may reveal
    unprecise contact between bodies. Check bodies
    design.
    Non manifold is created. This is problem.
    .
    .
    

Local fix

Problem summary

  • PART: BOOLEAN - NON-MANIFOLD EDGES CREATED DURING BOOLEAN OPERA
    TION.
    PART: BOOLEAN - NON-MANIFOLD EDGES
    CREATED DURING BOOLEAN OPERATION.
    .
    SCENARIO:
    0. Start CATIA.
    1. Open the file: "9534.CATPart". Workbench: "Part
    Design".
    2. Select "Body.2" with context menu "Body.2
    object"/ "Remove". Incident report is displayed:
    Non manifold edges have been created during
    boolean operation. Non manifold edges may reveal
    unprecise contact between bodies. Check bodies
    design.
    Non manifold is created. This is problem.
    .
    .
    

Problem conclusion

  • null
    ==========*===========*==========
    THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    .
    Incident Diagnosis
    Warning on non-manifold edge.
    .
    Correct Application
    An edge may be referred to twice by a loop, and
    cannot be forbidden. Hence there is a warning
    message for non-manifold.
    .
    When the pad dimension is set to 81 mm
    simplification of data takes place which removes
    the split faces due to Remove operation. However,
    this does not happen when the dimension is 55 for
    pad. As this is a tangent design case the stability of
    geometry cannot be difficult and the results may be
    undesired
    .
    User is trying to create a boolean operation
    between tangent design. This should be avoided as
    tangent design is instable.
    .
    Refer to Documentation - Part design - Assembling
    bodies.
    .
    Bypass:
    Do not use tangent design
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD64390

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-05-21

  • Closed date

    2007-06-01

  • Last modified date

    2007-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: