IBM Support

HD64366: GSD: PROJECTION- THE PROJECTION RESULT IS DIFFERENT IN DIFFEREN T CATIA RELEASES.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • GSD: PROJECTION- THE PROJECTION RESULT IS
    DIFFERENT IN DIFFERENT CATIA RELEASES.
    .
    SCENARIO.
    1. Start CATIA V5R16SP04. Work Bench-
    Generative Shape Design.
    2. Open the file Temp_V5R16.CATPart.
    3. Observe the Project.1. Projection Type- Normal
    and support is Revolute.1.
    4. Now start CATIA V5R15SP06. Work Bench-
    Generative Shape Design.
    5. Open the file Temp_V5R15.CATPart
    6. Observe the Project.1. It is different from the
    one in V5R16. This is the problem.
    Error: The Projection created V5R15 and V5R16
    are different.
    .
    .
    EXPECTED RESULT.
    The Projection created should not be different
    depending on the CATIA Release.
    .
    .
    

Local fix

Problem summary

  • GSD: PROJECTION- THE PROJECTION RESULT IS DIFFERENT IN DIFFEREN
    T CATIA RELEASES.
    GSD: PROJECTION- THE PROJECTION RESULT IS
    DIFFERENT IN DIFFERENT CATIA RELEASES.
    .
    SCENARIO.
    1. Start CATIA V5R16SP04. Work Bench-
    Generative Shape Design.
    2. Open the file Temp_V5R16.CATPart.
    3. Observe the Project.1. Projection Type- Normal
    and support is Revolute.1.
    4. Now start CATIA V5R15SP06. Work Bench-
    Generative Shape Design.
    5. Open the file Temp_V5R15.CATPart
    6. Observe the Project.1. It is different from the
    one in V5R16. This is the problem.
    Error: The Projection created V5R15 and V5R16
    are different.
    .
    .
    EXPECTED RESULT.
    The Projection created should not be different
    depending on the CATIA Release.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    .
    Incident Diagnosis.
    Projection of a curve on a surface made of several
    faces fails on some of these faces due to problems
    in initialisation and computation of the solution.
    .
    Correction Explanation.
    Correction of the initialisation and solution
    computation on revolution surfaces and cylinders.
    .
    Additional Information.
    Note this problem will also be fixed on V5R18SP02.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD64366

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-05-17

  • Closed date

    2007-09-13

  • Last modified date

    2007-11-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN SP51802

       UP07/11/13 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: