APAR status
Closed as program error.
Error description
ABSTRACT: DMU SPA: WRONG PRINCIPLE MOMENTS BASED ON CGR. . SCENARIO: 1.Start CATIA V5 with cache mode deactivated. 2.OPen the provided CATProduct. 3. Select the Measure Inertia command with at least Inertia / G selected and select the root product. 4.Export the result in a .txt file. 5. Start CATIA again with cache activated and density saved in the CGR file. 6. Open the provided CATProduct and stay in visualization mode. 7. Select the Measure Inertia command with at least Inertia / G selected and select the root product. 8. Export the result in a .txt file. . RESULT: The principal moments of two are different and moreover the exported measure is not the one given in the dialog box when selecting the CGR in the 3D EXPECTED RESULT: There should not be any difference between CGR and CATPart or at least between the read measure in the 3D during measurement and the exported file. .
Local fix
Problem summary
WRONG PRINCIPLE MOMENTS BASED ON CGR. ABSTRACT: DMU SPA: WRONG PRINCIPLE MOMENTS BASED ON CGR. . SCENARIO: 1.Start CATIA V5 with cache mode deactivated. 2.OPen the provided CATProduct. 3. Select the Measure Inertia command with at least Inertia / G selected and select the root product. 4.Export the result in a .txt file. 5. Start CATIA again with cache activated and density saved in the CGR file. 6. Open the provided CATProduct and stay in visualization mode. 7. Select the Measure Inertia command with at least Inertia / G selected and select the root product. 8. Export the result in a .txt file. . RESULT: The principal moments of two are different and moreover the exported measure is not the one given in the dialog box when selecting the CGR in the 3D EXPECTED RESULT: There should not be any difference between CGR and CATPart or at least between the read measure in the 3D during measurement and the exported file. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 19 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R18SP02. Incident Diagnosis Wrong principle moments based on CGR Correction Explanation density was not taken into account in computation of inertia matrix for visualisation mode (approximate compute) .
Temporary fix
Comments
APAR Information
APAR number
HD64358
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-05-17
Closed date
2007-09-21
Last modified date
2007-11-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R518 PSN SP51802
UP07/11/13 I 1000