HD64299: PART : MEASURE BETWEEN : ANGLE CAN NOT BE MEASURED BET INTERSEC TING SURFACES WHEN SEL MODE IS SURFACE ONLY

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PART : MEASURE BETWEEN : ANGLE CAN NOT BE
    MEASURED BET INTERSECTING SURFACES WHEN
    SEL MODE IS SURFACE ONLY
    .
    Scenario:
    1. Open attached CATPart.
    2. Launch Measure Between command. With default
    Sel 1 and Sel2 mode select any two intersecting
    surfaces.
    3. CATIA will display distance as well as angle.
    4. Now again launch Measure between command.
    This selects the Sel1 and Sel2 mode as Surface
    only.
    5. Now again measure above two surfaces, CATIA
    displays only distance, angle tab grayed out. This is
    the problem.
    .
    .
    

Local fix

Problem summary

  • PART : MEASURE BETWEEN : ANGLE CAN NOT BE MEASURED BET INTERSEC
    TING SURFACES WHEN SEL MODE IS SURFACE ONLY
    PART : MEASURE BETWEEN : ANGLE CAN NOT BE
    MEASURED BET INTERSECTING SURFACES WHEN
    SEL MODE IS SURFACE ONLY
    .
    Scenario:
    1. Open attached CATPart.
    2. Launch Measure Between command. With default
    Sel 1 and Sel2 mode select any two intersecting
    surfaces.
    3. CATIA will display distance as well as angle.
    4. Now again launch Measure between command.
    This selects the Sel1 and Sel2 mode as Surface
    only.
    5. Now again measure above two surfaces, CATIA
    displays only distance, angle tab grayed out. This is
    the problem.
    .
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 19 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED
    ON V5R18SP01
    .
    Incident Diagnosis
    Angle can nt be measured between two intersecting
    surfaces.The Surface only mode was not handled
    to display the angle. Hanlded the same in the code.
    .
    Correction Explanation
    Algorithm modified to manage such selections.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD64299

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-05-16

  • Closed date

    2007-07-27

  • Last modified date

    2007-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN SP51801

       UP07/10/01 I 1000