IBM Support

HD63812: MACHINING (AMG): THERE IS AN UNDERCUT IN ROUGHING

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MACHINING (AMG): THERE IS AN UNDERCUT IN
    ROUGHING OPERATION
    .
    1. Open .CATProcess
    2. Select Manufacturing Program.2 and Compute
    Tool Path,
    Forced computation
    3.Do replay the Roughing.2 operation
    4.The switch Optimize retract is on, but there is no
    tool retract
    movement optimization.
    5. Switch off Optimize retract
    6.Switch on Optimize retract
    7.Do replay the Roughing.2 operation again
    8.Now there is tool retract movement optimization.
    9. Perform video simulation
    10.The clamp has been undercut. ᄄ THIS IS THE
    PROBLEM
    .
    

Local fix

Problem summary

  • MACHINING (AMG): THERE IS AN UNDERCUT IN ROUGHING
    OPERATION
    MACHINING (AMG): THERE IS AN UNDERCUT IN
    ROUGHING OPERATION
    .
    1. Open .CATProcess
    2. Select Manufacturing Program.2 and Compute
    Tool Path,
    Forced computation
    3.Do replay the Roughing.2 operation
    4.The switch Optimize retract is on, but there is no
    tool retract
    movement optimization.
    5. Switch off Optimize retract
    6.Switch on Optimize retract
    7.Do replay the Roughing.2 operation again
    8.Now there is tool retract movement optimization.
    9. Perform video simulation
    10.The clamp has been undercut.   THIS IS THE
    PROBLEM
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA
    VERSION 5 RELEASE 18 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE
    FIXED ON V5R17SP06.
    .
    Incident Diagnosis
    Collisions with Part (or Check) appears on a
    SMG-Roughing Link trajectory, when
    toolpath is re-computed without modifying
    geometry.
    .
    Correction Explanation
    This is a particular case in which 'Automatic
    Safety Plane' is badly managed, and Link
    comes in collision with Part (or Check).
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD63812

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-04-26

  • Closed date

    2007-05-11

  • Last modified date

    2007-06-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R517 PSN SP51706

       UP07/06/28 I 1000