APAR status
Closed as Permanent restriction.
Error description
VISU : SCREEN GOES BLACK DURING FEW SECONDS WHEN SWITCH VISUALISATION TO WORKBENCHES Scenario: 1- Start CATIA 2- File - New Part 3- Select an axis and enter Sketcher (for example) Notice the screen goes black for 1/2 sec. 4- Exit Sketcher Notice the screen goes black for 1/2 sec again. .
Local fix
Problem summary
VISU : SCREEN GOES BLACK DURING FEW SECONDS WHEN SWITCH VISUALI SATION TO WORKBENCHES VISU : SCREEN GOES BLACK DURING FEW SECONDS WHEN SWITCH VISUALISATION TO WORKBENCHES Scenario: 1- Start CATIA 2- File - New Part 3- Select an axis and enter Sketcher (for example) Notice the screen goes black for 1/2 sec. 4- Exit Sketcher Notice the screen goes black for 1/2 sec again. .
Problem conclusion
null ==========*===========*========== THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Incident Diagnosis VISU : SCREEN GOES BLACK DURING FEW SECONDS WHEN SWITCH VISUALISATION TO WORKBENCHES Restriction Explanation Origin of the flash : The size of the graphic area is different between "Part Design" and "sketcher". The user interface must be refreshed. The size of the graphic area is different because the tool bar "Tools" contains a combo box to select the current tool in "Part Design". On UNIX, in the user interface, the toolbar with a combo is taller. The reason of the permanent restriction : The position of the tool bars are kept in the setting file. If we modify the size of the tool bars with a combo, all settings files are deprecated. The origin of the regression : The apparition of a combo in the tool bar "Tools" is the origin of the regression. By-Pass 1/ If the viewer isn't maximized in the graphic area, the problem doesn't occur. 2/ If the toolbar "Tools" isn't docked, the problem doesn't occur. 3/ If the tool bar "Graphic Properties" and "Tools" are in the same dock bar and in the same row, the problem doesn't occur. .
Temporary fix
Comments
APAR Information
APAR number
HD63375
Reported component name
CATIA V5 SOLARI
Reported component ID
569104000
Reported release
517
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-04-12
Closed date
2007-06-08
Last modified date
2007-06-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
08 June 2007