Error description
PART: CHAMFER - CHAMFER CANNOT BE CREATED. . SCENARIO: 0) Start CATIA. 1) Open the file: "T9441.CATPart". Workbench: "Part Design". 2) Click "Chamfer" icon. "Chamfer Definition" dialog box is displayed. 3) Select 1 edge in the solid on the geometry area. (Please see the "T9441.ppt" we send.) 4) Select "Length1/Length2" as "Mode:ᄄ 5) Input 7mm to "Length1:" 6) Input 7mm to "Length2:" 7) Click "OK". "Chamfer.1" is created. 8) Close CATIA. . In the case of R17SP3: 9) Start CATIA V5R17SP3Hotfix10. 10) Open the file: "T9441.CATPart". Workbench: "Part Design". 11) Click "Chamfer" icon. "Chamfer Definition" dialog box is displayed. 12) Select 1 edge in the solid on the geometry area. (Please see the "T9441.ppt" we send.) 13) Select "Length1/Length2" as "Mode:". 14) Input 7mm to "Length1:" 15) Input 7mm to "Length2:" 16) Click "OK". "Update Error" window is displayed. "Update Error" message. cst-51-design\Result of 51\Chamfer.1 Ribbon computation: The result contains at least one twisted surface. Decrease the parameter value(s) or change the operand(s). Chamfer is not created. This is problem. 17) Click "OK" on the window. 18) Click "Cancel" on the dialog box. . .
Local fix
Problem summary
PART: CHAMFER - CHAMFER CANNOT BE CREATED. PART: CHAMFER - CHAMFER CANNOT BE CREATED. . SCENARIO: 0) Start CATIA. 1) Open the file: "T9441.CATPart". Workbench: "Part Design". 2) Click "Chamfer" icon. "Chamfer Definition" dialog box is displayed. 3) Select 1 edge in the solid on the geometry area. (Please see the "T9441.ppt" we send.) 4) Select "Length1/Length2" as "Mode:? 5) Input 7mm to "Length1:" 6) Input 7mm to "Length2:" 7) Click "OK". "Chamfer.1" is created. 8) Close CATIA. . In the case of R17SP3: 9) Start CATIA V5R17SP3Hotfix10. 10) Open the file: "T9441.CATPart". Workbench: "Part Design". 11) Click "Chamfer" icon. "Chamfer Definition" dialog box is displayed. 12) Select 1 edge in the solid on the geometry area. (Please see the "T9441.ppt" we send.) 13) Select "Length1/Length2" as "Mode:". 14) Input 7mm to "Length1:" 15) Input 7mm to "Length2:" 16) Click "OK". "Update Error" window is displayed. "Update Error" message. cst-51-design\Result of 51\Chamfer.1 Ribbon computation: The result contains at least one twisted surface. Decrease the parameter value(s) or change the operand(s). Chamfer is not created. This is problem. 17) Click "OK" on the window. 18) Click "Cancel" on the dialog box. . .
Problem conclusion
Temporary fix
Comments
null ==========*===========*========== THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 19 GA level. . Incident Diagnosis: 1. In original Partbody with Length-Angle (7mm- 45deg angle), behavior is corrected. Now we get error message as expected for twisted surface. 2. In Copy-Pasted body in new CATPart, the error message is displayed as expected for Length- Angle, as well as Length-Length configuration. 3. For original Partbody, with Length-Length configuration (7mm-7mm for example), the twisted surface is not detected. . The chamfer is incorrect, twisted surface is generated. Because a very small twist has been detected now (around 0.2% of the surface). It is not detected, that is why the chamfer is seen as correct. . In the algorithm, we use a generic twist detection algorithm which may miss very small twists like this one. To fix this problem durably, a chamfer dedicated twist detection should be implemented, which would take into account specifications of the chamfer in order to be more reliable. This is a huge development, that has been plannned for R19GA. It cannot be implemented on R18 GA level. . Answer and Bypass: Change chamfer inputs. . .
APAR Information
APAR number
HD63082
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
517
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-04-03
Closed date
2007-06-29
Last modified date