APAR status
Closed as suggestion for future release.
Error description
PART : MEASURE INTERTIA : MEASURE OF 2D INERTIA IS NOT CORRECT. . Scenario: 1.Open the CATPart 2. Perform the 2D inertia measure on the L section . OBSERVATION: The result of measure of moment of area about the centroidal axis is not correct. . EXPECTED RESULT: The result of moment of area about the centroidal axis should be correct. . .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT WHICH CANNOT BE INCORPORATED IN VERSION V5R18 PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A REQUIREMENT FORM. . Incident Diagnosis Measure inertia for 2D around the centroidal axes system represents the 2D inertia tensor around the principal axes system. . Development request justification For 2 D inertia measurements, the present algorithm returns the 2D inertia for an object around the principal axes system only. Hence the stress tensor represents the 2D moment of inertia around the principal axes system, which are represented in red and green. The calculation and representation of 2D inertia around the centroidal axes needs a total changeover of the present 2D inertia tensor measurement. Thus, this impacting correction needs to be studied deeply before implementing. Hence this needs to be worked on an enhancement basis for a future release with customer's participation to define clearly the scope of the enhancement. . Answer and By-pass In order to calculate the 2D inertia about the centroidal axes system please perform the following steps. 1. Click on measure inertia and select the icon for surface/volumic item 2. Select the 2D face/surface of which the 2D intertia needs to be measured 3. The result is obtained which contains the surfacic moment of inertia about the centroidal axes. 4. In order to get the 2D moment of areas, divide the surfacic moment of inertia by the surfacic density. .
APAR Information
APAR number
HD62812
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
516
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-03-22
Closed date
2007-05-04
Last modified date
2007-05-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: