IBM Support

HD62774: LICENSING: ERROR OCCURS WHEN STARTED CATIA WITH CONCATENATED CATREFERENCESETINGS PATH

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • LICENSING: ERROR OCCURS WHEN STARTED
    CATIA WITH CONCATENATED
    CATREFERENCESETINGS PATH.
    .
    Scenario:
    1. Clear all the CATSettings
    2. Create two directories viz. d:/DM2 and
    d:/KWAHD2
    3. Put the two Licensing.CATSettings in these
    directories respectively.
    4. Open the CATEnv File
    5. For CATRefferenceCATSettings, put the path for
    these two directories as follows.
    CATRefferenceCATSettings= d:/DM2; d:/KWAHD2
    6. Save the CATEnv file.
    7. Launch Catia.
    .
    OBSERVATION:
    We get an error message and then the license
    manager window opens
    In the License manager window, the KWA license is
    grayed with a red lock and Not Granted. The DM2
    license is available.
    .
    EXPECTED RESULT:
    The KWA license should not be grayed and should
    appear unlocked so that it could be selected. Also
    we should obtain the HD2 license.
    .
    .
    

Local fix

Problem summary

  • LICENSING: ERROR OCCURS WHEN STARTED CATIA WITH CONCATENATED CA
    TREFERENCESETINGS PATH
    LICENSING: ERROR OCCURS WHEN STARTED
    CATIA WITH CONCATENATED
    CATREFERENCESETINGS PATH.
    .
    Scenario:
    1. Clear all the CATSettings
    2. Create two directories viz. d:/DM2 and
    d:/KWAHD2
    3. Put the two Licensing.CATSettings in these
    directories respectively.
    4. Open the CATEnv File
    5. For CATRefferenceCATSettings, put the path for
    these two directories as follows.
    CATRefferenceCATSettings= d:/DM2; d:/KWAHD2
    6. Save the CATEnv file.
    7. Launch Catia.
    .
    OBSERVATION:
    We get an error message and then the license
    manager window opens
    In the License manager window, the KWA license is
    grayed with a red lock and Not Granted. The DM2
    license is available.
    .
    EXPECTED RESULT:
    The KWA license should not be grayed and should
    appear unlocked so that it could be selected. Also
    we should obtain the HD2 license.
    .
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA.
    .
    Incident Diagnosis:
    An error occurs when CATIA is started with
    Concatenated CATReferenceSettings Path.
    .
    Restriction explanation.
    The license.catsettings file referring to HD2+KWA is
    not valuated when CATIA is launched with
    Concatenated CATReferenceSettings Path. Hence
    when CATIA is launched with the concatenated
    CATReferenceSettings Path there is an error
    message and the license is not granted.
    .
    By-pass
    1. Launch CATIA with the licences you want to
    have in the second concatenated directory
    (HD2+KWA for exemple) => license.CATSetting
    file will be freshly generated
    2. Close CATIA
    3. In the CATSetting folder, look for the newly
    generated license.CATSetting file
    4. Copy the license.CATSetting.
    5. Paste this file in the associated directory for
    this/those licence in the concatenated path
    6. In the CATEnv give the concatenation reference
    of this directories path in CATReferenceSettingspath
    7. Launch CATIA with Concatenated
    CATReferenceSettings Path .
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD62774

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-03-22

  • Closed date

    2007-03-23

  • Last modified date

    2007-05-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
11 May 2007