HD62364: PART : MULTI SECTION SOLID CAN NOT BE CREATED WITH SPECIFIC SKE TCHES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • PART : MULTI SECTION SOLID CAN NOT BE
    CREATED WITH SPECIFIC SKETCHES
    .
    Scenario:
    1. Open NUL-250.CATPart.
    2. Double-click at parameter/error_2 and change
    value to 6mm and then click OK.
    3. During update, error occurs. <= KO (Fig.1)
    .
    Error message :
    Invalid empty or missing input element. One
    mandatory input element is invalid, empty or
    missing. There is no solution for this operation.
    .
    Additional information :
    A-1. After step.3, double-click at
    parameter/error_1 and change value to100mm and
    then click OK.
    A-2. Geometry is created without any problem. <=
    OK (Fig.2)
    .
    Expected Result :
    Multi-section solid should be created without any
    problem in this case.
    .
    .
    

Local fix

Problem summary

  • PART : MULTI SECTION SOLID CAN NOT BE CREATED WITH SPECIFIC SKE
    TCHES
    PART : MULTI SECTION SOLID CAN NOT BE
    CREATED WITH SPECIFIC SKETCHES
    .
    Scenario:
    1. Open NUL-250.CATPart.
    2. Double-click at parameter/error_2 and change
    value to 6mm and then click OK.
    3. During update, error occurs. <= KO (Fig.1)
    .
    Error message :
    Invalid empty or missing input element. One
    mandatory input element is invalid, empty or
    missing. There is no solution for this operation.
    .
    Additional information :
    A-1. After step.3, double-click at
    parameter/error_1 and change value to100mm and
    then click OK.
    A-2. Geometry is created without any problem. <=
    OK (Fig.2)
    .
    Expected Result :
    Multi-section solid should be created without any
    problem in this case.
    .
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON :
    CATIA VERSION 5 RELEASE 17.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    CATIA VERSION 5 RELEASE 18 GA level
    .
    Scenario reproduced on reported R17SP03 level.
    .
    .
    

APAR Information

  • APAR number

    HD62364

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    517

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-03-07

  • Closed date

    2007-03-09

  • Last modified date

    2007-03-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R518 PSN

       UP