IBM Support

HD61844: ALTHOUGH A VALUE IS DEFINED FOR "UNDO STACK SIZE", IT IS POSSIB LE TO UNDO MORE TIMES THAN THAT VALUE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as user error.

Error description

  • Although a value is defined for "Undo Stack Size",
    it is possible to Undo more times than that value.
    .
    Preparation:
    1. Tools / Options / General / Performances
    2. Define "3" as Undo Stack size.
    .
    Scenario:
    1. Start CATIA V5R16 SP08,
    Open "TEST_Product.CATProduct".
    2. Double Click "SendParms.vbs".
    2-1. Key in 1 or 2, and Click "OK" Button.
    2-2. Click "OK" Button.
    2-3. Click "OK" Button.
    3. Update.
    4. Repeat 10 times from Step.2 to Step.3.
    5. Execute "Undo" 10 times.
    .
    KO !!
    Although Undo is set as three, Undo of ten times is
    possible.
    The memory management is negligent.
    .
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • .Incident Diagnosis
    Although a value is defined for "Undo Stack Size",
    it is possible to Undo more times than that value.
    .
    A great number of consecutive Undo actions can be
    performed while the option "Stack size" has been
    used to limit it.
    This is probably because the user started a global
    action. In that case, this limit does not apply so
    that it is possible to cancel the whole action.
    .
    .Correct Application
    R16 documentation says :
    Stack size Lets you indicate the number of
    commands (from 0 to 99) which can be undone for
    each document.
    Whatever the value, it is always possible to undo
    internal transitions (also called "local actions")
    inside the current command ("global action").
    .
    Note that a global action can be :
    - a command;
    - an edition in context (double-click).
    In "Undo with history" dialog box, the beginning of
    a global action can be recognized as it begins
    by "Start " (but the default "Select" command
    which does not stack a "Start Selection..." step).
    .
    Always open "Undo with history" dialog box when
    you do not understand Undo/Redo behaviors, it
    helps looking at which steps are stacked.
    .
    .Documentation Reference
    CATIA Infrastructure User Guide
    Customizing
    General / Performances
    .
    

APAR Information

  • APAR number

    HD61844

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED USE

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-02-16

  • Closed date

    2007-02-23

  • Last modified date

    2009-08-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
27 August 2009