HD61367: PD : MEASURE INERTIA : THE VALUES OF IOXG AND IOYG MEASURED BY MEASURE INERTIA 2D ARE EXACTLY OPPOSITE TO THAT MEASURED IN MEA

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • PD : MEASURE INERTIA : THE VALUES OF IoxG
    AND IoyG MEASURED BY MEASURE INERTIA 2D
    ARE EXACTLY OPPOSITE TO THAT MEASURED IN
    MEASURE INERTIA 3D
    .
    SCENARIO:
    SCENARIO:
    1.Open the Sent CATPart
    2.Select Measure Inertia icon
    3.Choose Measure Inertia 2D
    4.Surface is chosen
    Check IoxG and IoyG Values
    5.Choose Measure Inertia 3D
    6.Choose Surface again
    Check IoxG and IoyG Values
    ==== They are interchanged. This is the problem
    .
    

Local fix

Problem summary

  • PD : MEASURE INERTIA : THE VALUES OF IoxG AND IoyG MEASURED BY
    MEASURE INERTIA 2D ARE EXACTLY OPPOSITE TO THAT MEASURED IN MEA
    S
    PD : MEASURE INERTIA : THE VALUES OF IoxG
    AND IoyG MEASURED BY MEASURE INERTIA 2D
    ARE EXACTLY OPPOSITE TO THAT MEASURED IN
    MEASURE INERTIA 3D
    .
    SCENARIO:
    SCENARIO:
    1.Open the Sent CATPart
    2.Select Measure Inertia icon
    3.Choose Measure Inertia 2D
    4.Surface is chosen
    Check IoxG and IoyG Values
    5.Choose Measure Inertia 3D
    6.Choose Surface again
    Check IoxG and IoyG Values
    ==== They are interchanged. This is the problem
    .
    

Problem conclusion

  • THIS MODIFICATION WILL BE INCLUDED IN CATIA
    DOCUMENTATION DELIVERED WITH CATIA
    VERSION 5 RELEASE 18
    .
    Documentation Reference
    DMU Space Analysis user's Guide -
    Basic Tasks -
    Measuring 2D Inertia -
    .
    MODIFICATION:
    The DMU Space Analysis documentation has
    beenupdated accordingly
    The axes of inertia are highlighted and a bounding
    box parallel to the axes and bounding the selected
    item also appears.
    To obtain the same type of inertia matrix for
    similar shapes independent from the space
    orientation of the surface being measured (i.e.
    invariant); the x-axis is set along the Principal
    Moment axis with the smallest value (M1), i.e.
    along the longest side (red) and the y-axis is set
    along the second Principal Moment axis (M2)
    (green)
    Principal Axis matrix (A) expresses the axes
    orientations in the Global Axis System
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD61367

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    516

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-02-01

  • Closed date

    2007-03-09

  • Last modified date

    2007-03-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"516","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
09 March 2007