IC61286: BLANK BROWSER SCREEN RETURNED INSTEAD OF HATS ADMIN CONSOLE WHEN Z/OS WAS BOOTSTRAP AND ORB LISTENER PORTS NOT SET TO 2809.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Environment: HATS V6 customer running WAS V6 on z/OS.
    On some of the customer's machines, when the bootstrap address
    port and orb listener address ports are set to something besides
    the default value of 2809, attempting to invoke the HATS
    Administrative Console from a browser returns a completely blank
    browser screen.  Setting the bootstrap and orb listener address
    ports to 2809 resolves the problem.  On some other systems in
    the customer's environment, HATS Administrative Console works
    well regardless of what port is used as the bootstrap and
    orb listener address port in WAS.
    Other symptoms are CORBA.COMM_FAILURE errors in WAS, and in HATS
    traces, when the ports are set to something besides 2809, this
    message may be seen:
    ConnectorException, hostName=SMTSYS01.dtcc.com, port=2809,
    ADMC0017E: Could not create an RMI connector to connect to host
    SMTSYS01.dtcc.com at port 2809
    

Local fix

  • Change WAS BOOTSTRAP_ADDRESS port value and ORB_LISTENER_ADDRESS
    port values to 2809 (both are same in z/OS environment).
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: HATS Administrative Console users where      *
    *                 the RMI bootstrap address of the HATS        *
    *                 server differs from the default value of     *
    *                 2809.  This issue is specific to the z/OS    *
    *                 platform.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The HATS Administrative Console         *
    *                      browser page appears completely blank   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    The HATS Administrative Console logic assumed that port 2809
    should always be the default value for the RMI bootstrap
    address.  It did not use the adminPortNum value in the
    runtime.properties file to set the default port value. When the
    HATS Administrative Console interface was initializing, it
    always tried to contact port 2809 first.  If port
    2809 was unreachable or did not respond, then the HATS
    Administrative Console might show a blank panel instead of the
    Admin interface.
    

Problem conclusion

  • The HATS Administrative Console logic will use the value
    specified for adminPortNum in the
    runtime.properties or runtime-debug.properties file to
    determine the default RMI bootstrap address port value to use
    when initializing.
    This fix will be available in HATS 6.0.10, 7.0.0.6, 7.1.0.4,
    and 7.5.0.2.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IC61286

  • Reported component name

    HATS V6 ZSERIES

  • Reported component ID

    5724L0401

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-05-28

  • Closed date

    2009-07-30

  • Last modified date

    2009-07-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HATSRUNT
    

Fix information

  • Fixed component name

    HATS V6 ZSERIES

  • Fixed component ID

    5724L0401

Applicable component levels

  • R600 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXKAY-2","label":"Rational Host Access Transformation Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]