IBM Support

HE10849: Chained dimensions problem - Dimensions jumping on drawing

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Open the CATDrawing in CATIA.
    2. Move the chain dimension using mouse for repositioning.
    Problem:
    The dimension behaves erratically and does not move with the mou
    se cursor.
    Expected Result:
    User should be able to reposition the chain dimension normally u
    sing the mouse cursor.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open the CATDrawing in CATIA.
    2. Move the chain dimension using mouse for repositioning.
    Problem:
    The dimension behaves erratically and does not move with the
    mouse cursor.
    Expected Result:
    User should be able to reposition the chain dimension
    normally using the mouse cursor.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON V6-R2013 GA levels.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP3.
    Additional Closure Information:
    Incident Diagnosis:
    Chained dimensions problem - Dimensions jumping on drawing
    Technical explanation of the defect:
    Issue with broken view and system. Command modify position to
    take account of future breaks, but in certain cases, it must
    not be done.
    Technical explanation of the correction:
    All break in view are now handle. Dimensions don't jump
    anymore when we move them.
    Possible by-pass and/or correction limitation:
    None
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE10849

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-30

  • Closed date

    2011-12-05

  • Last modified date

    2011-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R521 PSN

       UP