  • .Scenario:
    1. Open an Assembly in CATIA.
    2. Activate Sectionning Command.
    3. In the sectionning definition window, set the section
    correctly and then click on OK.
    4. Observe the spec tree.
    Problem:
    The sectionning vanishes and it does not appear in the
    specification tree either.
    Expected Result:
    The user should be able to view the sectionning from the
    specification tree. Section should appear on the spec tree.
    

Local fix

  • empty
    

Problem summary

  • .Scenario:
    1. Open an Assembly in CATIA.
    2. Activate Sectionning Command.
    3. In the sectionning definition window, set the section
    correctly and then click on OK.
    4. Observe the spec tree.
    Problem:
    The sectionning vanishes and it does not appear in the
    specification tree either.
    Expected Result:
    The user should be able to view the sectionning from the
    specification tree. Section should appear on the spec tree.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    Incident Diagnosis:
    Sectioning is not kept in Assembly Design
    Reason:
    The section features created without valid DMU Space Analysis
    license (e.g. SPA) will be non-persistent, i.e. on OK,
    neither section reps is retained in visualization nor the
    spec tree node for section created is retained.
    HD2 license does not authorize any DMU Space Analysis Product
    (e.g. SPA). So section created will not be persisted on OK.
    This is a packaging / licensing restriction existing in CATIA
    for section features.
    Also recently this restriction was documented in R21 level
    Sectioning Doc under BR10000102619.
    By-Pass:
    None
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE09348

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-08-05

  • Closed date

    2011-08-12

  • Last modified date

    2011-08-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 August 2011