Error description

  • Process:
    1) Start CATIA V5R20
    2) Open Product1.CATProduct
       Workbench      : Assembly Design
       > Product.1 is opened normally, and the "Incident Report"
    window is not displayed.
       > Product.2 is opened normally.
       > This is key point.
    3) Close Product.1.
    4) Open the file  : Product2.CATProduct
       Workbench      : Assembly Design
       > Product.2 opens, but an Incident Report window is
    displayed. This is 1st problem!!!!
    5) Select "File / Save Management?" from the menubar.
       > "Save Management" window is diaplayed.
    6) Confirm the number of the data displayed by "Save
    Management" window.
       > but Product.2 is not displayed in "Save Management"
    window. This is 2nd problem!!!!
    .
    Expected Result:
    When Product.2 is opened, an "Incident Report" window must
    not be displayed.
    And, Product.2 should be displayed in "Save Management"
    window.
    .
    

Local fix

  • empty
    

Problem summary

  • Process:
    1) Start CATIA V5R20
    2) Open Product1.CATProduct
       Workbench      : Assembly Design
       > Product.1 is opened normally, and the "Incident Report"
    window is not displayed.
       > Product.2 is opened normally.
       > This is key point.
    3) Close Product.1.
    4) Open the file  : Product2.CATProduct
       Workbench      : Assembly Design
       > Product.2 opens, but an Incident Report window is
    displayed. This is 1st problem!!!!
    5) Select "File / Save Management???" from the menubar.
       > "Save Management" window is diaplayed.
    6) Confirm the number of the data displayed by "Save
    Management" window.
       > but Product.2 is not displayed in "Save Management"
    window. This is 2nd problem!!!!
    .
    Expected Result:
    When Product.2 is opened, an "Incident Report" window must
    not be displayed.
    And, Product.2 should be displayed in "Save Management"
    window.
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON Virtual Design  VERSION V5R22
    GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP7.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP2.
    .
    Additional Closure Information:
    Technical explanation of the defect:
    Problem when opening a BRep container that is under an
    Knwoledge proxy container.
    .
    Technical explanation of the correction:
    The container is now correctly taken into account.
    .
    Possible by-pass and/or correction limitation:
    No possible by pass but the problem is fixed now.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE08338

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-06-28

  • Closed date

    2011-09-05

  • Last modified date

    2011-09-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R520 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
05 September 2011