APAR status
Closed as unreproducible in next release.
Error description
ABSTRACT: SWI: Error on opening STEP file in Solidworks . SCENARIO: The Step-by-step scenario using PLMDB is: 1) Launch SolidWorks 2011 and login to SmarTeam with the Admin account 2) From within SolidWorks select file and open 3) From the open dialog box select the icon for system folders 4) Browse to a sample assembly file that comes with the installation of SolidWorks, for this example we used C:\Program Files\SolidWorks Corp\SolidWorks\tutorial\tolanalyst\introduction\ gear box complete.sldasm 5) Select open once you have located this sample SolidWorks assembly file 6) With the assembly file loaded select the file pulldown menu and the save as command 7) From the project manager menu select the cancel button 8) From the save as dialog box select a location to save the STEP file for our example we used c:\temp 9) Once you have selected the path to store the STEP file, select the drop down box next to Save as Type and select either STEP AP203 or AP214 either format will produce the same results. 10) Select the save option. 11) After the STEP file has been saved, Select the file pulldown and select close to close the assembly file that you just opened 12) Select file and open again, and select the system folders icon 13) Browse to the location where the STEP file was saved (c:\temp) 14) To the right of the filename box select the file type STEP AP203/214 (*step,*stp) extension 15) Highlight the gear box complete.sldasm.STEP file and select open . Result: As the step file is being loaded, you will receive the error message that An error has occurred and SolidWorks needs to re-start 17) Restart SolidWorks again and this time do not load the SmarTeam integration. Repeat the process of opening the STEP file. 18) This time the STEP file will load without any issue, since the SmarTeam integration is turned off.
Local fix
empty
Problem summary
ABSTRACT: SWI: Error on opening STEP file in Solidworks . SCENARIO: The Step-by-step scenario using PLMDB is: 1) Launch SolidWorks 2011 and login to SmarTeam with the Admin account 2) From within SolidWorks select file and open 3) From the open dialog box select the icon for system folders 4) Browse to a sample assembly file that comes with the installation of SolidWorks, for this example we used C:\Program Files\SolidWorks Corp\SolidWorks\tutorial\tolanalyst\introduction\ gear box complete.sldasm 5) Select open once you have located this sample SolidWorks assembly file 6) With the assembly file loaded select the file pulldown menu and the save as command 7) From the project manager menu select the cancel button 8) From the save as dialog box select a location to save the STEP file for our example we used c:\temp 9) Once you have selected the path to store the STEP file, select the drop down box next to Save as Type and select either STEP AP203 or AP214 either format will produce the same results. 10) Select the save option. 11) After the STEP file has been saved, Select the file pulldown and select close to close the assembly file that you just opened 12) Select file and open again, and select the system folders icon 13) Browse to the location where the STEP file was saved (c:\temp) 14) To the right of the filename box select the file type STEP AP203/214 (*step,*stp) extension 15) Highlight the gear box complete.sldasm.STEP file and select open . Result: As the step file is being loaded, you will receive the error message that An error has occurred and SolidWorks needs to re-start 17) Restart SolidWorks again and this time do not load the SmarTeam integration. Repeat the process of opening the STEP file. 18) This time the STEP file will load without any issue, since the SmarTeam integration is turned off.
Problem conclusion
THE PROBLEM WAS SUBMITTED ON : I-PLM Collaborative Innovation VERSION V5R20. THIS PROBLEM IS NOT REPRODUCIBLE ON : I-PLM Collaborative Innovation VERSION V5R22 GA level I-PLM Collaborative Innovation VERSION V5R20 SP7. I-PLM Collaborative Innovation VERSION V5R21 SP1. Additional Closure Information: THE PROBLEM WAS SUBMITTED ON : ENOVIA SMARTEAM VERSION V5R20. THIS PROBLEM IS NOT REPRODUCIBLE ON : ENOVIA SMARTEAM VERSION V5R22 GA level ENOVIA SMARTEAM VERSION V5R20 SP7. ENOVIA SMARTEAM VERSION V5R21 SP1.
Temporary fix
Comments
APAR Information
APAR number
HE08308
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
520
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-28
Closed date
2011-09-02
Last modified date
2011-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMARTEAM NT>XP
Fixed component ID
569199970
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 September 2011