APAR status
Closed as program error.
Error description
ABSTRACT: The selected product in the "Edit Distance and Band Analysis" is not cleared after "Replace Component " is performed for two or more times SCENARIO: 0) Start CATIA. 1) Open "Product_TOP.CATProduct" "W/B DMU Space Analysis". 2) Select "View/Tree Expansion/Expand Second Level". >>Tree is expanded. 3) Select "Distance and Band Analysis" icon. >>"Edit Distance and Band Analysis" window is displayed. 4) Select "Between two selections" as Type. Select "ProductA" as "Selection1". Select "Part2" as "Selection2". -> This is a key point. 5) Click "Apply " and "OK" button. >>"Distance.1" is created in tree. 6) Select "ProductB" and select "Replace Component" using contextual menu. >>"File Selection" window is displayed. 7) Select "ProductC" and click "Open". >>Impact On Replace" window is displayed. 8) Click "OK". 9) Double click "Distance.1" in tree. >>"Edit Distance and Band Analysis" window is displayed. >>The "Selection2" is cleared. 10) Activate "Selection2" in the "Edit Distance and Band Analysis" window. 11) Select "Part3" instance in tree. 12) Click "Apply" and click "OK" button. 13) Select "ProductC" and select "Replace Component" using contextual menu. >>"File Selection" window is displayed. 14) Select "ProductD" or "ProductB" and click "Open". >>Impact On Replace" window is displayed. 15) Click "OK". 16) Double click "Distance.1" in tree. >>"Edit Distance and Band Analysis" window is displayed. RESULT: The "Selection2" is not cleared in "Edit Distance and Band Analysis" window. EXPECTED RESULT: The selected product in the "Selection2" should be cleared after "Replace Component" is performed for two or more times.
Local fix
empty
Problem summary
ABSTRACT: The selected product in the "Edit Distance and Band Analysis" is not cleared after "Replace Component " is performed for two or more times SCENARIO: 0) Start CATIA. 1) Open "Product_TOP.CATProduct" "W/B DMU Space Analysis". 2) Select "View/Tree Expansion/Expand Second Level". >>Tree is expanded. 3) Select "Distance and Band Analysis" icon. >>"Edit Distance and Band Analysis" window is displayed. 4) Select "Between two selections" as Type. Select "ProductA" as "Selection1". Select "Part2" as "Selection2". -> This is a key point. 5) Click "Apply " and "OK" button. >>"Distance.1" is created in tree. 6) Select "ProductB" and select "Replace Component" using contextual menu. >>"File Selection" window is displayed. 7) Select "ProductC" and click "Open". >>Impact On Replace" window is displayed. 8) Click "OK". 9) Double click "Distance.1" in tree. >>"Edit Distance and Band Analysis" window is displayed. >>The "Selection2" is cleared. 10) Activate "Selection2" in the "Edit Distance and Band Analysis" window. 11) Select "Part3" instance in tree. 12) Click "Apply" and click "OK" button. 13) Select "ProductC" and select "Replace Component" using contextual menu. >>"File Selection" window is displayed. 14) Select "ProductD" or "ProductB" and click "Open". >>Impact On Replace" window is displayed. 15) Click "OK". 16) Double click "Distance.1" in tree. >>"Edit Distance and Band Analysis" window is displayed. RESULT: The "Selection2" is not cleared in "Edit Distance and Band Analysis" window. EXPECTED RESULT: The selected product in the "Selection2" should be cleared after "Replace Component" is performed for two or more times.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA V5R20 SP7. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP2. Additional Closure Information: Technical explanation of the defect: Selected product is not cleared after performing Replace operation more than once. Technical explanation of the correction: Issue is now corrected for multiple replace operations.
Temporary fix
Comments
APAR Information
APAR number
HE08078
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-21
Closed date
2011-07-18
Last modified date
2011-07-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
18 July 2011