Error description
. SCENARIO: 1. Open Catia V5 2. Create a new CATPart Workbench-Generative Shape Design 3. Select circle command Circle definition dialog box appears 4. Select circle type as centre and radius, centre by creating point at x=0, y=0, z=0, support as YZ plane, radius as 0.51mm an d whole circle as circle limitation and Click ok. 5. Select Fill command. 6. Select circle and put deviation value as 0.005mm. Update error message appears As ???Update Error Fill.1 The Fill failed. There is a continuity gap of 1.02mm between elements. Try to improve your geometry.??? . PROBLEM: The fill failed. There is a continuity gap of 1.02mm between ele ments. . EXPECTED RESULT: The fill should be done without error.
Local fix
empty
Problem summary
. SCENARIO: 1. Open Catia V5 2. Create a new CATPart Workbench-Generative Shape Design 3. Select circle command Circle definition dialog box appears 4. Select circle type as centre and radius, centre by creating point at x=0, y=0, z=0, support as YZ plane, radius as 0.51mm and whole circle as circle limitation and Click ok. 5. Select Fill command. 6. Select circle and put deviation value as 0.005mm. Update error message appears As ???Update Error Fill.1 The Fill failed. There is a continuity gap of 1.02mm between elements. Try to improve your geometry.??? . PROBLEM: The fill failed. There is a continuity gap of 1.02mm between elements. . EXPECTED RESULT: The fill should be done without error.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R22 GA level. Additional Closure Information: Technical explanation of the defect: In deviation is ON,a tiny circle is judged as gap mistakenly, which brings fill surface error. Technical explanation of the correction: The correction has been done so that fill should be done without error.
Temporary fix
Comments
APAR Information
APAR number
HE08063
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-20
Closed date
2011-10-21
Last modified date
2011-10-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R521 PSN
UP