IBM Support

HE07072: THE EDGE FILLET WITH BLEND CORNER CANNOT BE CREATED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Launch CATIA.
    2. Create a part with a corner and three adjacent edges.
    3. GSD/Part Design WB.
    4. Edge Fillet > More
    5. Radius = 5mm
    6. Setback distance = 5mm
    7. Blend corner(s) > MB3 > Create by edges
    8. Click ?Preview? button
    Result:
    In V5R20GA level, Fillet creation is previewed properly.
    In higher levels, CATIA throws an internal error message.
    Expected Result:
    The ?Preview? button should display proper ?Edge Fillet with
    the Blend corner?, like the behavior in V5R20GA level.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Launch CATIA.
    2. Create a part with a corner and three adjacent edges.
    3. GSD/Part Design WB.
    4. Edge Fillet > More
    5. Radius = 5mm
    6. Setback distance = 5mm
    7. Blend corner(s) > MB3 > Create by edges
    8. Click ?Preview? button
    Result:
    In V5R20GA level, Fillet creation is previewed properly.
    In higher levels, CATIA throws an internal error message.
    Expected Result:
    The ?Preview? button should display proper ?Edge Fillet with
    the Blend corner?, like the behavior in V5R20GA level.
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP1.
    Additional Closure Information:
    INCIDENT DIAGNOSIS:
    The Edge Fillet with same "Radius and Setback Distance" and
    enabled "Blend Corner" cannot be Previewed.
    CLOSURE DESCRIPTION:
    Error in creation occurred due to change in algorithm.
    Backed up with previous algorithm. No more problem in Fillet
    Creation and Preview.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE07072

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-18

  • Closed date

    2011-05-30

  • Last modified date

    2011-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R521 PSN SP52101

       UP11/07/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 July 2011