IBM Support

HE07002: PS : BOM : VISUALISE IN BILL OF MATERIALS IS NOT KEPT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Scenario:
    Data Specific.
    In a Specific CATProduct user opens the properties of an
    particular Instance and checks the checkbox "Visualise in
    Bill of Materials' and confirms OK. On reopnening the
    properties for the same instance again the checkbox
    "Visualise in Bill of Materials" remains Unchecked.
    Problem:
    "Visualise in Bill Of Materials" is unchecked. Further more
    if the user creates a view in a CATDrawing, the BOM created
    by Advanced BOM has the component even if the visualization
    in BOM is not active on any instance.
    Expected result:
    The Checkbox "Visualise in Bill of Materials" must be checked
    and the BOM must not be created when the visualization in BOM
    is not active on any Instance.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    Data Specific.
    In a Specific CATProduct user opens the properties of an
    particular Instance and checks the checkbox "Visualise in
    Bill of Materials' and confirms OK. On reopnening the
    properties for the same instance again the checkbox
    "Visualise in Bill of Materials" remains Unchecked.
    Problem:
    "Visualise in Bill Of Materials" is unchecked. Further more
    if the user creates a view in a CATDrawing, the BOM created
    by Advanced BOM has the component even if the visualization
    in BOM is not active on any instance.
    Expected result:
    The Checkbox "Visualise in Bill of Materials" must be checked
    and the BOM must not be created when the visualization in BOM
    is not active on any Instance.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA
    Additional Closure Information:
    Incident Diagnosis:
    Visualise in Bill Of Material is not kept.
    Reason:
    To visualise Bill Of Material ,any Assembly Product needs to
    have certain attributes defined in CATIA.
    With the customer data provided ,it is a part (not a type of
    Assembly Product supported by CATIA)in which the required
    attribute is missing.Thus not possible to visualise the BOM
    for that particular part.
    Also, CATDUA can work on only Assembly Product defined by
    DS,thus the data can not be corrected, Since the part made by
    the customer is not made as per the standards of CATIA.
    Hence the issue can be closed as Permanent Restriction.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE07002

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-16

  • Closed date

    2011-06-06

  • Last modified date

    2011-06-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
06 June 2011