APAR status
Closed as program error.
Error description
Scenario: 1) Remove All CATSettings 2) Start CATIA R19SP6 3) Tools / Options / Catlog Editor The catalog favourites list is as follows: ISO.catalog US.catalog JIS.catalog EN.catalog 4) Tools / Mecanical Standard Parts / ISO.catalogs -> The ISO.catalog is loaded 5) Measure the time taken for the Catalog Browerwindow to appear 6) Exit CATIA . 7) Remove All CATSettings 8) Start CATIA R19SP6 9) Tools / Options / Catlog Editor Add the customer catalog at the top of the catalog favourites li st as follows: ELECTRICAL_LINKED.catalog US.catalog JIS.catalog EN.catalog 10) Tools / Mecanical Standard Parts / ISO catalogs -> The ISO.catalog is loaded 11) Measure the time taken for the Catalog Browerwindow to appea r -> It takes longer because both the ELECTRICAL_LINKED and the IS O catalog are loaded . Expected result: If the catalog favourites list is customized only the ISO catlog should be loaded when Tools / Mechanical Standard Parts / ISO catalogs is selected .
Local fix
empty
Problem summary
Scenario: 1) Remove All CATSettings 2) Start CATIA R19SP6 3) Tools / Options / Catlog Editor The catalog favourites list is as follows: ISO.catalog US.catalog JIS.catalog EN.catalog 4) Tools / Mecanical Standard Parts / ISO.catalogs -> The ISO.catalog is loaded 5) Measure the time taken for the Catalog Browerwindow to appear 6) Exit CATIA . 7) Remove All CATSettings 8) Start CATIA R19SP6 9) Tools / Options / Catlog Editor Add the customer catalog at the top of the catalog favourites list as follows: ELECTRICAL_LINKED.catalog US.catalog JIS.catalog EN.catalog 10) Tools / Mecanical Standard Parts / ISO catalogs -> The ISO.catalog is loaded 11) Measure the time taken for the Catalog Browerwindow to appear -> It takes longer because both the ELECTRICAL_LINKED and the ISO catalog are loaded . Expected result: If the catalog favourites list is customized only the ISO catlog should be loaded when Tools / Mechanical Standard Parts / ISO catalogs is selected .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA V5R20 SP7. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP1. Additional Closure Information: Technical explanation of the defect: By default when catalog browser is launched using OpenCatalogBrowser method it is trying to load the last opened catalog, if launch for the first time it is checking favorites (tools -> options -> Catlog Editor), in case of BR (user provider catalogue) this take lot of time (1 min). Technical explanation of the correction: Call method OpenCatalogBrowser using mode 'CATCatalogDisplayNoDfltCatalog' (do not try load default catalog). Possible by-pass and/or correction limitation:
Temporary fix
Comments
APAR Information
APAR number
HE06975
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-13
Closed date
2012-02-07
Last modified date
2012-02-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
07 February 2012