IBM Support

HE06918: SEVERE PERFORMANCE PROBLEM WHEN OPENING FILES IN SOLIDWORKS WITH THE SMARTEAM INTEGRATION ENABLED

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • Performance issue with the SmarTeam Integration for
    SolidWorks.
    When opening assemblies that contain part files or a part
    that is highly configured (sample part files attached to the
    SR), it takes an extremely long time to
    open the files in SolidWorks.
    Simply opening the part files in SolidWorks with the SmarTeam
    Integration enabled causes a long load time versus opening
    the part file without the SmarTeam
    Integration enabled.
    We have also noticed that during the opening of the part
    files with the SmarTeam Integration enabled, the user's
    Windows TEMP folder (%TEMP%) begins to populate
    with large .TMP files being created.
    This begins to fill the Windows TEMP folder with these .TMP
    files. Once the part file is opened, the .TMP file creation
    is also completed.
    The environment is SmarTeam V5R20 SP5 with SolidWorks 2011
    SP3.0.
    Use Client - Windows XP 64 bit SP2 and Server - Windows 2008
    Server.
    PLMDB can be used.
    Next preferences were set:
    DMT expand setting set to 1.
    Default preference SolidWorks.LoadPropertiesOnOpen=NO.
    The Client SmarTeam Work directory is on Local drive of the
    Client computer.
    No any additional (except of standard) setting or changes
    were reported for SW and SmarTeam.
    Vault Services should run.
    The vaults were located on the Foundation server.
    No any Mapped drive and no SmarTeam Work directory on a
    Network drive is used.
    The following are the steps to reproduce the issue:
    1) Start SolidWorks without the SmarTeam Integration enabled
    2) Open the SolidWorks part file 11005-0009.SLDPRT .
    3) After the part file is opened in SolidWorks, go to the
    Windows TEMP folder by going to Start, Run, enter %TEMP% and
    hit enter.
    a. Note that no large file size .TMP files exist in the
    folder
    4) Close SolidWorks
    5) Open SolidWorks
    6) Enable the SmarTeam Integration add-in. Login to SmarTeam
    as user "admin" in PLMDB
    7) Open the SolidWorks part file named 11005-0009.SLDPRT.
    8) After the part file is finally opened in SolidWorks, go to
    the Windows TEMP Folder by gong to Start, Run, enter %TEMP%
    and hit enter
    a. Note the large temp files and the time it takes to open
    the file is considerably longer
    Current Results:
    In step 7 above, the time it takes to open the SolidWorks
    part is considerably longer that the time it took to open the
    same part file in Step 2.
    BE Note: In BE tests in step 2 there were 15 s needed for
    opening the Part file, while in step 7 there were 6 min
    needed for opening the same Part file.
    Expected Results:
    The time it takes to open the part file as performed during
    step 7 (with the SmarTeam Integration enabled) should be
    similar to the time it takes to the same Part file as
    performed in step 2 (without the SmarTeam Integration
    enabled).
    BE Note: After the fix the time in in step 7 cannot be the
    same as in step 2, besides a difference in the times should
    be reasonable, say to be ranged in per cents, but not to be
    greater in 24 times, as reported.
    The fix should be tested for both cases: for the File Saved
    to SmarTeam, Checked In and Copied previously onto Local Work
    directory, and for the File that is not Saved to SmarTeam,
    but placed onto Local Work directory.
    Duplicate of BR10000105534.
    

Local fix

  • empty
    

Problem summary

  • Performance issue with the SmarTeam Integration for
    SolidWorks.
    When opening assemblies that contain part files or a part
    that is highly configured (sample part files attached to the
    SR), it takes an extremely long time to
    open the files in SolidWorks.
    Simply opening the part files in SolidWorks with the SmarTeam
    Integration enabled causes a long load time versus opening
    the part file without the SmarTeam
    Integration enabled.
    We have also noticed that during the opening of the part
    files with the SmarTeam Integration enabled, the user's
    Windows TEMP folder (%TEMP%) begins to populate
    with large .TMP files being created.
    This begins to fill the Windows TEMP folder with these .TMP
    files. Once the part file is opened, the .TMP file creation
    is also completed.
    The environment is SmarTeam V5R20 SP5 with SolidWorks 2011
    SP3.0.
    Use Client - Windows XP 64 bit SP2 and Server - Windows 2008
    Server.
    PLMDB can be used.
    Next preferences were set:
    DMT expand setting set to 1.
    Default preference SolidWorks.LoadPropertiesOnOpen=NO.
    The Client SmarTeam Work directory is on Local drive of the
    Client computer.
    No any additional (except of standard) setting or changes
    were reported for SW and SmarTeam.
    Vault Services should run.
    The vaults were located on the Foundation server.
    No any Mapped drive and no SmarTeam Work directory on a
    Network drive is used.
    The following are the steps to reproduce the issue:
    1) Start SolidWorks without the SmarTeam Integration enabled
    2) Open the SolidWorks part file 11005-0009.SLDPRT .
    3) After the part file is opened in SolidWorks, go to the
    Windows TEMP folder by going to Start, Run, enter %TEMP% and
    hit enter.
    a. Note that no large file size .TMP files exist in the
    folder
    4) Close SolidWorks
    5) Open SolidWorks
    6) Enable the SmarTeam Integration add-in. Login to SmarTeam
    as user "admin" in PLMDB
    7) Open the SolidWorks part file named 11005-0009.SLDPRT.
    8) After the part file is finally opened in SolidWorks, go to
    the Windows TEMP Folder by gong to Start, Run, enter %TEMP%
    and hit enter
    a. Note the large temp files and the time it takes to open
    the file is considerably longer
    Current Results:
    In step 7 above, the time it takes to open the SolidWorks
    part is considerably longer that the time it took to open the
    same part file in Step 2.
    BE Note: In BE tests in step 2 there were 15 s needed for
    opening the Part file, while in step 7 there were 6 min
    needed for opening the same Part file.
    Expected Results:
    The time it takes to open the part file as performed during
    step 7 (with the SmarTeam Integration enabled) should be
    similar to the time it takes to the same Part file as
    performed in step 2 (without the SmarTeam Integration
    enabled).
    BE Note: After the fix the time in in step 7 cannot be the
    same as in step 2, besides a difference in the times should
    be reasonable, say to be ranged in per cents, but not to be
    greater in 24 times, as reported.
    The fix should be tested for both cases: for the File Saved
    to SmarTeam, Checked In and Copied previously onto Local Work
    directory, and for the File that is not Saved to SmarTeam,
    but placed onto Local Work directory.
    Duplicate of BR10000105534.
    

Problem conclusion

  • THE PROBLEM HAS BEEN FOUND TO BE ANOTHER SYMPTOM OF THE
    PROBLEM REPORTED IN  APAR HE00093 OR THE ANSWER MADE FOR THIS
    DUPLICATE APAR APPLIES ALSO TO THE CURRENT PROBLEM.
    Additional Closure Information:
    Duplicate of BR10000097527 / IR-072329
    

Temporary fix

Comments

  • This APAR is a duplicate of HE00093
    

APAR Information

  • APAR number

    HE06918

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    520

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-05-12

  • Closed date

    2011-07-18

  • Last modified date

    2011-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
18 July 2011