IBM Support

HE05587: PART: WALL THICKNESS ANALYSIS: THICKNESS RESULT IS NOT DISPLAYED ON THE PARTBODY WHEN CATPART IS SAVED AND RE-OPENED.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as user error.

Error description

  • SCENARIO:
    1. Create a new CATPart
    Workbench- Part design
    2. Create a simple pad
    3. Launch Wall thickness Analysis command
    4. Select the Pad
    5. Select on the fly option in Option tab
    6. Select Run and click OK
    7. Double click on Wall Thickness Analysis and move the
    cursor over Pad
    Observation:
    The thickness value is displayed.-This is correct behavior.
    .
    8. Save the CATPart but do not close it.
    9. Again double click on Wall Thickness Analysis and move the
    cursor over Pad
    Observation:
    The thickness value is displayed.-This is correct behavior.
    10. Close the CATPart and re-open it
    11. Double-click ???WallThicknessAnalysis.???
    12. Confirm the ???On the fly??? check box is checked.
    13. Move the cursor to any position on the Pad.
    Observation:
    The thickness values are not displayed.-This is the problem.
    14. Again click on run button and move the cursor over Pad
    Observation:
    The thickness value is displayed.-This is correct behavior.
    In the case of using ???Section cut???(select ???Section??? tab)
    ,
    Warning message is displayed as
    ???Warning
    First launch the analysis by clicking Run.???
    .
    However there is no such message in the case of ???On the fly???
    
    option.
    PROBLEM:
    By opening the CATPart, thickness values should be displayed
    on the fly whenever ???on the fly option is checked???
    .
    EXPECTED RESULT:
    By opening the CATPart, Thickness values should be displayed
    on the fly even if Run button is not clicked.
    

Local fix

  • empty
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • .
    INCIDENT DIAGNOSIS:
    On the fly Thickness result is not displayed on the Partbody
    when CATPart is saved and re-opened.
    .
    CORRECT APPLICATION:
    Whenever On the fly function is available, it is stated in
    status bar (bottom left corner) as follows.
    ???fly over the part to get thickness under cursor (if on the
    fly selected) and click a planer face/surface to position
    section(if Section cut selected)???
    However On the fly function is not available as long as the
    analysis has not been launched since opening the part. In
    this case, status bar shows message as ???click Run to launch
    the analysis???
    When editing Wall Thickness Analysis feature, analysis must
    be launched again to get the results on the fly as mentioned
    in the status bar. i.e. User will have to Run the analysis
    again to get on the fly results.
    

APAR Information

  • APAR number

    HE05587

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED USE

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-25

  • Closed date

    2011-03-30

  • Last modified date

    2011-03-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
30 March 2011