HE05491: FILL SURFACE IS CREATED, BUT A CURVE IS NOT ON THE SURFACE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario:
    1. Build the attached sample workspace
    2. Launch the CATIA
    3. Open the attached part document
    4. Run the ???TestAddinC??? command in ???Samplelb??? toolbar
    It created a surface (Fill) using
    CATGSMCreateTopologicalAutomaticFill method
    Actual Result:
    Curve.2 used for fill does not seem to be on created surface
    Expected Result:
    Curve.2 is a bad shape. So it is preferred to have error
    message.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Build the attached sample workspace
    2. Launch the CATIA
    3. Open the attached part document
    4. Run the ?TestAddinC? command in ?Samplelb? toolbar
    It created a surface (Fill) using
    CATGSMCreateTopologicalAutomaticFill method
    Actual Result:
    Curve.2 used for fill does not seem to be on created surface
    Expected Result:
    Curve.2 is a bad shape. So it is preferred to have error
    message.
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP1.
    Additional Closure Information:
    Technical explanation of the defect:
    A Multi Domain wire has to be taken into account.
    After that an error message concerning the joining of input
    curves will be returned because there is an invalid input
    curve
    Technical explanation of the correction:
    Multi domain wires are detected so that in this case the join
    of curves to Fill is impossible
    An error message is returned.
    Possible by-pass and/or correction limitation:
    NONE
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE05491

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-23

  • Closed date

    2011-05-02

  • Last modified date

    2011-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R521 PSN SP52101

       UP11/07/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: