IBM Support

HE05367: IMPOSSIBLE TO CREATE AN ISOMETRIC VIEW IN A DRAWING FROM MODEL F ILE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Scenario:
    1. Open the V4 .model file in V5.
    2. Open a new drawing and select create isometric view.
    3. Without zooming or panning click on the model to create an
    isometric view of the object.
    Problem:
    The isometric view is not generated. An error crops up.
    Expected Result:
    The isometric view should be generated without any errors.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open the V4 .model file in V5.
    2. Open a new drawing and select create isometric view.
    3. Without zooming or panning click on the model to create an
    isometric view of the object.
    Problem:
    The isometric view is not generated. An error crops up.
    Expected Result:
    The isometric view should be generated without any errors.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA.
    Additional Closure Information:
    Incident Diagnosis:
    Drawing view generation applied on a V4 model failed on
    specific points of view in Exact mode.
    
    Technical Reason:
    The V4 model is locally invalid. There are 2 faces without
    closed boundary.
    We can see from the topological area that the visualization
    of the body is not complete.
    This view generation requires silhouette computation, which
    is crossing the topological area in the isometric view.
    This is the reason why an error is seen in the exact mode for
    the isometric view.
    In approximate mode, the bad faces are ignored because of the
    visualisation issue, so there is no error detected.
    By-Pass:
    CopyPaste the V4model as Result in a new CATPart file; the
    Import V4 to V5 removes the topology and fixes the model. So,
    all the views can be generated.
    If the user wants to work with V4 data, it is possible to do
    so using the approximate mode.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE05367

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    519

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-18

  • Closed date

    2011-03-22

  • Last modified date

    2011-03-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: