Scenario : 1- File / Open the CATDrawing file Note that this drawing has been created on CATIA V5R11 It contains one view with angle dimensions, distance dimensions, diameter dimensions and so on .... 2- MB3 on the view, then select 'Copy' 3- Create a new Drawing 4- MB3 on Sheet.1 in this new Drawing 5- Select 'Paste' Result : Angle dimensions are not displayed. Half diameter dimension is incorrectly displayed Expected Result All the dimensions should be displayed after Copy and Paste.
Local fix
empty
Problem summary
Scenario : 1- File / Open the CATDrawing file Note that this drawing has been created on CATIA V5R11 It contains one view with angle dimensions, distance dimensions, diameter dimensions and so on .... 2- MB3 on the view, then select 'Copy' 3- Create a new Drawing 4- MB3 on Sheet.1 in this new Drawing 5- Select 'Paste' Result : Angle dimensions are not displayed. Half diameter dimension is incorrectly displayed Expected Result All the dimensions should be displayed after Copy and Paste.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP6. Additional Closure Information: Diagnosis: Copy/Paste transaction of Views with dimensions relying on old corrupted "connectors to geometry" components can fail. Reason: DCR_8 is a new DUA rule that cleans such "connectors to geometry" Technical explanation of the defect: Regarding the dimensions that are not pasted (angle dimensions): This behavior is correct : those dimensions use the numerical display format called "ANGLE,DG" which is a customized format. As mentioned in the Interactive Drafting online documentation in the section Basic Tasks/Copying and Pasting Elements, "When pasting elements from a drawing to another drawing which uses a different standard: some elements (such as dimensions) may not be supported by this standard. In this case, such non-supported elements will not be created." In other words, the target drawing document must use the same standard than the original one. Use the extracted standard XML. If you create the new drawing using this standard, the paste performs correctly. Technical explanation of the correction: . Possible by-pass and/or correction limitation: Use the right standard for target drawing.
Temporary fix
Comments
APAR Information
APAR number
HE05355
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-03-18
Closed date
2011-05-03
Last modified date
2011-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 May 2011