HE05256: PART : THREAD/TAP RECOMMENDED VALUE ERROR IN INCORRECT UNITS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When Thread/Tap definition is applied to a hole (pocket
    feature) with incorrect diameter, based on the standard,
    recommended diameter is reported in MM when Inches is
    specified as the current Length unit.
    .
    Scenario:
    1. Place an xls thread table into CATIA install \standard
    dir.
    2. Create a simple part
    3. Thread/Tap Command. Specify Lateral Face and Limit Face on
    the hole in part.
    4. Change Type to the specific table
    5. Select a thread.
    ==> the warning message displays to say: "Feature Definition
    Error: ... Value recommended by your standard is 10.5842"
    The recommended value is in MM, regardless of Length unit
    defined in CATSettings. Should report recommended value of
    .4167
    .
    

Local fix

  • empty
    

Problem summary

  • When Thread/Tap definition is applied to a hole (pocket
    feature) with incorrect diameter, based on the standard,
    recommended diameter is reported in MM when Inches is
    specified as the current Length unit.
    .
    Scenario:
    1. Place an xls thread table into CATIA install \standard
    dir.
    2. Create a simple part
    3. Thread/Tap Command. Specify Lateral Face and Limit Face on
    the hole in part.
    4. Change Type to the specific table
    5. Select a thread.
    ==> the warning message displays to say: "Feature Definition
    Error: ... Value recommended by your standard is 10.5842"
    The recommended value is in MM, regardless of Length unit
    defined in CATSettings. Should report recommended value of
    .4167
    .
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R22 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP1.
    .
    Additional Closure Information:
    Technical explanation of the defect:
    The warning message does not take into account the unit used
    in the session and the reference file
    .
    Technical explanation of the correction:
    The problem has been corrected in modifying the warning
    message in order to take into account the unit of the
    reference file.
    .
    Possible by-pass and/or correction limitation:
    No possible by-pass but the problem is fixed now.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE05256

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-15

  • Closed date

    2011-05-06

  • Last modified date

    2011-07-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R521 PSN SP52101

       UP11/07/18 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 July 2011