Error description

  • 1. Open the CATProcess in Advanced Machining workbench.
    2. Expand the Process.
    3. RightMouseButton on Pencil.1 and Replay Tool Path
    **Problem - As memory consumption increases, eventually an
    error occurs:
    Manufacturing Error - Allocation failed (196616 bytes). An
    allocation of 196616 bytes failed. Close the open documents
    that are useless, save your work, restart a new session.
    R20 SP1 is able to complete the computation without drastic
    memory consumption.
    

Local fix

  • empty
    

Problem summary

  • 1. Open the CATProcess in Advanced Machining workbench.
    2. Expand the Process.
    3. RightMouseButton on Pencil.1 and Replay Tool Path
    **Problem - As memory consumption increases, eventually an
    error occurs:
    Manufacturing Error - Allocation failed (196616 bytes). An
    allocation of 196616 bytes failed. Close the open documents
    that are useless, save your work, restart a new session.
    R20 SP1 is able to complete the computation without drastic
    memory consumption.
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN DELMIA.
    Additional Closure Information:
    A fix has been delivered in R20SP4 to increase the accuracy
    of the machining and to have a better control of the
    machining tolerance. This leads to increase the size of the
    memory used to compute the toolpath and can lead to
    allocation failure on win32 OS.
    By-Pass:
    Two possible workarounds exist :
    1. Reducing the machining tolerance in the Rework area
    definition (from 0.01mm to 0.02mm) allows to get as accurate
    results as in R20SP1 without any allocation failure on win32
    OS.
    2. Keep machining tolerance 0.01mm in the Rework area
    definition but use win64 OS. It's not possible to come back
    to R20SP1 behaviour because this would lead to a regression
    in toolpath accuracy.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE05235

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    520

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-03-14

  • Closed date

    2011-03-18

  • Last modified date

    2011-03-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
18 March 2011