APAR status
Closed as Permanent restriction.
Error description
SCENARIO: 1. File / New / Drawing 2. Click New View icon Indicate position 3. Click Line icon Select origin point of the View 4. Indicate place and line is created =End point is not created at origin point Additional info: If creating line using Snap to Point function, end point is created. . PROBLEM: End point is not created at origin point . . EXPECTED RESULT: End point should be created even if creating line using origin point. There is no end point, impossible to move line This behavior is same as Sketcher. If this is CATIA specification, please let us know the description in documentation.
Local fix
empty
Problem summary
SCENARIO: 1. File / New / Drawing 2. Click New View icon Indicate position 3. Click Line icon Select origin point of the View 4. Indicate place and line is created =End point is not created at origin point Additional info: If creating line using Snap to Point function, end point is created. . PROBLEM: End point is not created at origin point . . EXPECTED RESULT: End point should be created even if creating line using origin point. There is no end point, impossible to move line This behavior is same as Sketcher. If this is CATIA specification, please let us know the description in documentation.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA. Additional Closure Information: Incident Diagnosis: Create line using origin point, end point is not created. . Restriction Explanation: When creating a line or any curve in Drafting/Sketcher, when selecting the origin as an end point, the origin is shared between view/sketch axis system and the created curve. No new end point is created. Smart pick re-uses as much as possible existing points during geometry creation. This is a specification for smart pick. . An end point is created if "snap option" is selected because the coincidence with the origin is not detected (no coincidence icon is shown). . By-Pass: It is possible to separate the created curve from the origin by selecting the origin and launching "break" command.
Temporary fix
Comments
APAR Information
APAR number
HE05034
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
520
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-03-08
Closed date
2011-03-11
Last modified date
2011-03-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
11 March 2011