APAR status
Closed as program error.
Error description
SCENARIO: - When a electrical diagram file is open, an warning message appears showing some specific CATFcts are not found. This diagram file has no link OR relation with these CATFcts. EXPECTED RESULT: The Diagram file should be opened without message.
Local fix
empty
Problem summary
SCENARIO: - When a electrical diagram file is open, an warning message appears showing some specific CATFcts are not found. This diagram file has no link OR relation with these CATFcts. EXPECTED RESULT: The Diagram file should be opened without message.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP6. Additional Closure Information: Technical explanation of the defect: Due to infrastructure change, Broken links or probable ghost links are now reported for documents that may not be necessary to open particular document. Technical explanation of the correction: User should be able to specify the fcts those are not necessary/ are obsolete, Application can then get this information and won't report them as a broken links. User can define the text file containing list of obsolete fcts , he has in his environment. This text file will be integrated with CATIA through the following Project Resource Management (PRM) Resource. Resource Name="ObsoleteFcts" Description="List of obsolete fct files" All the files listed in the text file will not be reported as missing links during operation such as "file open" NOTE: - PRM must be activated first, if it is not active OR current then fix cannot be invoked. Bypass: Yes, create dummy CATFct files with same name (which are missing) in the directory pointed by CATGraphicPath of your CATIA environment.
Temporary fix
Comments
APAR Information
APAR number
HE04130
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-09
Closed date
2011-05-05
Last modified date
2011-05-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R520 PSN