IBM Support

HE04130: SPECIFIC .FCT FILES ARE NOT FOUND WHEN OPENING THE DIAGRAM FILE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • SCENARIO:
    - When a electrical diagram file is open, an warning message
    appears showing some specific CATFcts are not found.
    This diagram file has no link OR relation with these CATFcts.
    EXPECTED RESULT:
    The Diagram file should be opened without message.
    

Local fix

  • empty
    

Problem summary

  • SCENARIO:
    - When a electrical diagram file is open, an warning message
    appears showing some specific CATFcts are not found.
    This diagram file has no link OR relation with these CATFcts.
    EXPECTED RESULT:
    The Diagram file should be opened without message.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP6.
    Additional Closure Information:
    Technical explanation of the defect:
    Due to infrastructure change, Broken links or probable ghost
    links are now reported for
    documents that may not be necessary to open particular
    document.
    Technical explanation of the correction:
    User should be able to specify the fcts those are not
    necessary/ are obsolete, Application
    can then get this information and won't report them as a
    broken links.
    User can define the text file containing list of obsolete
    fcts , he has in his environment.
    This text file will be integrated with CATIA through the
    following Project Resource Management (PRM) Resource.
    Resource Name="ObsoleteFcts" Description="List of obsolete
    fct files"
    All the files listed in the text file will not be reported as
    missing links during operation
    such as "file open"
    NOTE: - PRM must be activated first, if it is not active OR
    current then fix cannot be invoked.
    Bypass: Yes, create dummy CATFct  files with same name (which
    are missing) in the directory pointed by CATGraphicPath of
    your CATIA environment.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE04130

  • Reported component name

    CATIA V5 WIN 64

  • Reported component ID

    569165000

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-02-09

  • Closed date

    2011-05-05

  • Last modified date

    2011-05-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 WIN 64

  • Fixed component ID

    569165000

Applicable component levels

  • R520 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
05 May 2011