IBM Support

HE03218: SOLIDWORKS SAVE OPERATION ABORT ON NOT FOUND FILES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • When a SolidWorks Assembly contains suppressed parts and
    these parts are not accessible through file system, then the
    Interface run into a loop or abort the save operation.
    Reproduction scenario : [Please open attached video file
    "SR00044234-Scenario.wrf"]
    1.) Save two new SolidWorks parts to disk without SmarTeam
    interaction
    2.) Create a new assembly and assembly both parts
    3.) Suppress one of them
    4.) Save the assembly and close it
    5.) Rename the suppressed part filename
    6.) Reopen the assembly
    7.) Save the assembly to SmarTeam
    Current Result:-
    => Probably only the assembly will save to SmarTeam , it's up
    the the order of parts in SolidWorks
    Note :- As I guess because of the first suppressed part in
    the structure save operation get quits and as a result only
    assembly object is saved
    => The asterix sign in title bar will still remain for SW
    assembly (ASM incompletely saved to SmarTeam, CheckIn not
    possible)
    Expected Result:-
    1) SW assembly should get save (excluding to the suppressed
    parts), meaning for this assembly if the first part is
    suppressed it should make save structure with another
    unsuppressed parts
    2) With above point 1, SW assembly should available without
    the asterix sign (after SmarTeam Save)
    

Local fix

  • empty
    

Problem summary

  • When a SolidWorks Assembly contains suppressed parts and
    these parts are not accessible through file system, then the
    Interface run into a loop or abort the save operation.
    Reproduction scenario : [Please open attached video file
    "SR00044234-Scenario.wrf"]
    1.) Save two new SolidWorks parts to disk without SmarTeam
    interaction
    2.) Create a new assembly and assembly both parts
    3.) Suppress one of them
    4.) Save the assembly and close it
    5.) Rename the suppressed part filename
    6.) Reopen the assembly
    7.) Save the assembly to SmarTeam
    Current Result:-
    => Probably only the assembly will save to SmarTeam , it's up
    the the order of parts in SolidWorks
    Note :- As I guess because of the first suppressed part in
    the structure save operation get quits and as a result only
    assembly object is saved
    => The asterix sign in title bar will still remain for SW
    assembly (ASM incompletely saved to SmarTeam, CheckIn not
    possible)
    Expected Result:-
    1) SW assembly should get save (excluding to the suppressed
    parts), meaning for this assembly if the first part is
    suppressed it should make save structure with another
    unsuppressed parts
    2) With above point 1, SW assembly should available without
    the asterix sign (after SmarTeam Save)
    

Problem conclusion

  • THE PROBLEM WAS SUBMITTED ON :
        I-PLM Collaborative Innovation VERSION V5R19.
    THIS PROBLEM IS NOT REPRODUCIBLE ON :
    I-PLM Collaborative Innovation VERSION V5R20 SP6.
    Additional Closure Information:
    Issue is Unreproduciable on Enovia SmarTeam V5R20SP6
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE03218

  • Reported component name

    SMARTEAM NT>XP

  • Reported component ID

    569199970

  • Reported release

    519

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-01-10

  • Closed date

    2011-03-17

  • Last modified date

    2011-03-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SMARTEAM NT>XP

  • Fixed component ID

    569199970

Applicable component levels

  • R520 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: