APAR status
Closed as Permanent restriction.
Error description
SCENARIO: This scenario is for specific data. Create a simple pad. 1. Select ???Apply Material??? icon. 2. Select CATMaterial.??? 3. Apply material on ???Part.??? 4. Close ???Library??? dialog box. 5. Click ???Formula??? icon. 6. Find ???CompAngleWarpWeft??? parameter and ???CompRatioWarpWe ft??? parameter. 7. Click ???Cancel??? button on ???Formulas??? dialog box. 8. Click ???Formula??? icon again. 9. Find ???CompAngleWarpWeft??? parameter and ???CompRatioWarpWe ft??? parameter. RESULTS: The two parameters are disappeared from ???Formulas??? dialog box. EXPECTED RESULT: The two parameters, CompAngleWarpWeft and CompRatioWarpWeft, always should be in ???Formulas??? dialog box.
Local fix
empty
Problem summary
SCENARIO: This scenario is for specific data. Create a simple pad. 1. Select ???Apply Material??? icon. 2. Select CATMaterial.??? 3. Apply material on ???Part.??? 4. Close ???Library??? dialog box. 5. Click ???Formula??? icon. 6. Find ???CompAngleWarpWeft??? parameter and ???CompRatioWarpWe ft??? parameter. 7. Click ???Cancel??? button on ???Formulas??? dialog box. 8. Click ???Formula??? icon again. 9. Find ???CompAngleWarpWeft??? parameter and ???CompRatioWarpWe ft??? parameter. RESULTS: The two parameters are disappeared from ???Formulas??? dialog box. EXPECTED RESULT: The two parameters, CompAngleWarpWeft and CompRatioWarpWeft, always should be in ???Formulas??? dialog box.
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA Additional Closure Information: Incident Diagnosis: CompAngleWarpWeft and CompRatioWarpWeft disappeared from Formula Editor in parameter section after Cancel . Restriction Explanation: Those attributes has been added to the definition of composites facet for material due to new function in composites product. To avoid modification of material library during application of it, the attributes are not added automatically during this stage (stage-when material is applied to Part/feature). The reason for that is that material should not be modified (as they are supposed to be frozen and validated, and users who re-use (apply material) it should not modify them. These parameters are added if user edits the material (in its library) go to composites tab and just click OK . Only activating the composites tab will modify the material library and therefore the library needs to be saved. . By-Pass: As mentioned above, edit the material, go to composites tab and click ok and save the library. Then by applying the material, all properties are available consistently.
Temporary fix
Comments
APAR Information
APAR number
HE02622
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-12-10
Closed date
2011-03-18
Last modified date
2011-03-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
18 March 2011