APAR status
Closed as program error.
Error description
Summary: CAT_VBO_ALLOWED Variable causes crash when running catvba script User problem: User cannot take advantage of the variable that speeds up graphi cs If they do, then this causes a crash when using certain vba scri pts Scenario: 1. Make sure you have the environment variable CAT_VBO_ALLOWED=1 set and Example_DT.xls held in the same directory as EXAMPLE.CA TAnalysis and EXAMPLE PART.CATPart 2. Open EXAMPLE.CATAnalysis 3. Run the script (CFD.catvba > RunFormDOE) 4. Select the icon ???Run through DEO??? - May need to do this 3 -4 times 5. CATIA crashes Problem occurs on Windows 64bits machine with ATI FirePro V5800 (Driver 8.702.0.0) Graphics card.
Local fix
empty
Problem summary
Summary: CAT_VBO_ALLOWED Variable causes crash when running catvba script User problem: User cannot take advantage of the variable that speeds up graphics If they do, then this causes a crash when using certain vba scripts Scenario: 1. Make sure you have the environment variable CAT_VBO_ALLOWED=1 set and Example_DT.xls held in the same directory as EXAMPLE.CATAnalysis and EXAMPLE PART.CATPart 2. Open EXAMPLE.CATAnalysis 3. Run the script (CFD.catvba > RunFormDOE) 4. Select the icon ?Run through DEO? - May need to do this 3-4 times 5. CATIA crashes Problem occurs on Windows 64bits machine with ATI FirePro V5800 (Driver 8.702.0.0) Graphics card.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP6. Additional Closure Information: Description: CAT_VBO_ALLOWED Variable causes crash when running catvba script . Diagnosis: Conflict between VBO and Hyperthreading leading to a crash or a freeze. . By-pass: Do not activated VBO
Temporary fix
Comments
APAR Information
APAR number
HE01546
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-04
Closed date
2011-05-17
Last modified date
2011-05-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: